Seitenansicht 64
Reference Manual
00809-0600-4026, Rev BA
December 2011
5-9
Rosemount Process Radar
NOTE
Rosemount 5400 Series Transmitters with Flameproof/Explosion-proof
Output have a built-in barrier; no external barrier needed.
Intrinsically Safe Power Supply
Type n Approvals: Non-Sparking / Energy Limited Power Supply
Power
Supply
Approved
IS Barrier
Field Communicator
PC
F
OUNDATION fieldbus
IS Parameters:
U
i
=30 V, I
i
= 300 mA,
P
i
=1.5 W, C
i
=4.95 nF, L
i
=0 H,
FISCO IS Parameters:
U
i
=17.5 V, I
i
= 380 mA
P
i
=5.32 W, C
i
=4.95 nF, L
i
<1 μH
Rosemount 5400 Series Radar Level Transmitter
Fieldbus
Modem
Power
Supply
Field Communicator
PC
Rosemount 5400 Series Radar Level Transmitter
F
OUNDATION fieldbus:
U
n
=32 V
Fieldbus
Modem