Reference Manual
00809-0100-4801, Rev FA
October 2010
Rosemount 3051S Series
3-28
5. Locate the saved transmitter configuration file.
a. Select “Offline”
b. Select “Saved Configuration”
c. Select either “Internal Flash Contents” or “Configuration EM
Contents” depending on where the configuration was stored per
step 2b.
6. Use the DOWN ARROW to scroll through the list of configurations in the
memory module, and use the RIGHT ARROW to select and retrieve the
desired configuration.
7. Select “Send” to transfer the configuration to the receiving transmitter.
8. Select “OK” after the control loop is set to manual.
9. After the configuration has been sent, select “OK” to acknowledge that
the loop can be returned to automatic control.
When finished, the Field Communicator informs you of the status. Repeat
steps 3 through 9 to configure another transmitter.
NOTE
The transmitter receiving cloned data must have the same software version
(or later) as the original transmitter.
AMS v7.0 creating a Reusable Copy
To create a reusable copy of a configuration perform the following procedure:
1. Completely configure the first transmitter.
2. Select View then User Configuration View from the menu bar (or click the
toolbar button).
3. In the User Configuration window, right click and select New from the
context menu.
4. In the New window, select a device from the list of templates shown, and
click OK.
5. The template is copied into the User Configurations window, with the tag
name highlighted; rename it as appropriate and press Enter.
NOTE
A device icon can also be copied by dragging and dropping a device template
or any other device icon from AMS Explorer or Device Connection View into
the User Configurations window.
The “Compare Configurations” window appears, showing the Current values
of the copied device on one side and mostly blank fields on the other (User
Configuration) side.
6. Transfer values from the current configuration to the user configuration
as appropriate or enter values by typing them into the available fields.
7. Click Apply to apply the values, or click OK to apply the values and close
the window.
Kommentare zu diesen Handbüchern