Reference Manual
00809-0100-4801, Rev FA
October 2010
A-35
Rosemount 3051S Series
Lower Housing Material for FF, Extension Length for EF (High Side)
(6)
Flush Flanged Seal Extended Flanged Seal
Standard Standard
0 None — ★
2 — 2-in. (50 mm) ★
4 — 4-in. (100 mm) ★
6 — 6-in. (150 mm) ★
A 316 SST — ★
B Alloy C-276 — ★
D Carbon Steel — ★
Flushing Connection Quantity and Size (Lower Housing, High Side)
Flush Flanged Seal Extended Flanged Seal
Standard Standard
0 None None ★
1 1 (
1
/4 - 18 NPT) — ★
3 2 (
1
/4 - 18 NPT) — ★
7 1 (
1
/2 - 14 NPT) — ★
9 2 (
1
/2 - 14 NPT) — ★
Wireless Options (Requires option code X and wireless PlantWeb housing)
Update Rate
Standard Standard
WA User Configurable Update Rate ★
Operating Frequency and Protocol
Standard Standard
3 2.4 GHz DSSS, IEC 62591 (WirelessHART) ★
Omnidirectional Wireless Antenna
Standard Standard
WK External Antenna ★
WM Extended Range, External Antenna ★
SmartPower
™
Standard Standard
1
(7)
Compatible with Black Power Module (I.S. Power Module Sold Separately) ★
Other Options (Include with selected model number)
Diaphragm Thickness
Expanded
SC 0.006-in. (150 µm) available with 316L SST and Alloy C-276
Flushing Plug, Vent/Drain Valve
Standard Standard
SD Alloy C-276 plug(s) for flushing connection(s) ★
SG 316 SST plug(s) for flushing connection(s) ★
SH 316 SST vent/drain for flushing connection(s) ★
Gasket Material
Standard Standard
SJ PTFE gasket (for use with flushing connection ring) ★
Expanded
SN Grafoil
®
gasket (for use with flushing connection ring)
Code Conformance
Standard Standard
ST
(8)
Wetted Materials Compliance to NACE MRO175/ISO 15156, MRO103 ★
Table A-3. Rosemount 3051S Liquid Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.