External ground screw assembly
Standard Standard
D4 External Ground Screw Assembly
Product certifications
Standard Standard
E1 ATEX Flameproof
I1 ATEX Intrinsic Safety
N1 ATEX Type n
ND ATEX Dust
K1 ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
E4 TIIS Flameproof
I4 TIIS Intrinsic Safety
K4 TIIS Flameproof and Intrinsic Safety (combination E4 and I4)
E5 FM Explosion-proof, Dust Ignition-proof
I5 FM Intrinsically Safe, Division 2
K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
E6 CSA Explosion-proof, Dust Ignition-proof, Division 2
I6 CSA Intrinsically Safe
K6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and
I6)
E7 IECEx Flameproof, Dust Ignition-proof
I7 IECEx Intrinsic Safety
N7 IECEx Type n
K7 IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7)
E2
(4)
INMETRO Flameproof
I2
(4)
INMETRO Intrinsic Safety
K2
(4)
INMETRO Flameproof, Intrinsic Safety (combination of E2 and I2)
E3
(4)
China Flameproof
I3
(4)
China Intrinsic Safety
KA
(5)
ATEX and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E1, E6, I1, and I6)
KB FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of
E5, E6, I5, and I6)
KC
(5)
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
KD
(5)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, E6, E1, I5, I6, and I1)
Digital display
Standard Standard
M5 PlantWeb LCD Display
Terminal blocks
Standard Standard
T1 Transient terminal block
Conduit Electrical Connector
GE
(6)
M12, 4-pin, Male Connector (eurofast
®
)
GM
(6)
A size Mini, 4-pin, Male Connector (minifast
®
)
Typical model number: 300SMV M R 1A C22 M5
(1) RTD Sensor must be ordered separately.
(2) Material specified is cast as follows: CF-8M is the cast version of 316 SST, CF-3M is the cast version of 316L SST, CW-12MW is the cast version of Alloy C-276, M-30C is the cast
version of Alloy 400. For housing, material is aluminum with polyurethane paint.
(3) For use with Flowmeters with integral RTDs.
(4) Contact an Emerson Process Management representative for availability.
(5) RTD cable not available with this option.
(6) Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Non-Incendive approval (option code I5), install in accordance with Rosemount drawing 03151-1206
to maintain outdoor rating (NEMA 4X and IP66).