Seitenansicht 85
76 Transmitter Configuration and Use: Series 1000 and 2000 Transmitters
Using the Transmitter continued
7.8.2 Viewing the API totalizers and inventories
To view the current values of the API totalizers and inventories, use the procedures described in
Section 7.5.
7.8.3 Controlling totalizers and inventories
Table 7-3 shows all of the totalizer and inventory functions and which configuration tools you can use
to control them.
With the display
Table 7-4 shows how you can control the totalizers and inventories with the display.
Table 7-3 Totalizer and inventory control methods
Function name Communicator
ProLink II
software Display
(1)
(1) Model 1700 and 2700 transmitters with display only.
Stop all totalizers and inventories (mass, volume, and API) Yes Yes Yes
(2)
(2) If enabled. See Section 8.14.1.
Start all totalizers and inventories (mass, volume, and API) Yes Yes Yes
(2)
Reset mass totalizer only Yes Yes Yes
(2)
Reset volume totalizer only Yes Yes Yes
(2)
Reset API totalizer only No No Yes
(2)
Simultaneously reset all totalizers (mass, volume, and API) Yes Yes Yes
(2)
Simultaneously reset all inventories (mass, volume, and API) No Yes
(3)
(3) If enabled in the ProLink II preferences.
No
Table 7-4 Totalizer and inventory control with the display
To accomplish this Press this sequence of buttons
Stop all totalizers and
inventories (mass,
volume, and API)
(1)
Scroll until a totalizer value appears (the word TOTAL appears in the lower left corner of
the display). It does not matter whether the total is mass, volume, or API.
Select.
If a password is required (CODE? appears), enter it and Select.
(2)
Scroll until STOP appears beneath the current totalizer value.
Select (
YES alternates with STOP).
Select (all totalizers and inventories stop).
Start all totalizers and
inventories (mass,
volume, and API)
(1)
Scroll until a totalizer value appears (the word TOTAL appears in the lower left corner of
the display). It does not matter whether the total is mass, volume, or API.
Select.
If a password is required (
CODE? appears), enter it and Select.
(2)
Scroll until START appears beneath the current totalizer value.
Select (
YES alternates with START).
Select (all totalizers and inventories start).
Seitenansicht 85