Motor Over Temperature Fault
This fault is indicated by the display showing a “M”. This indicates a fault involving
excessive motor temperature.
Potential causes for the “M” High DC Bus fault
Motor thermal sense switch is open due to excessive heat build up in the motor.
Flexing of a non-flex cable
Improper wiring
Defective thermal switch internally in the motor
Noise
“M” “Motor Over Temperature Fault
Motor Thermal
Switch open
due to excessive
internal heat
Allow Motor to cool
Approximately 30 mimutes
Flexing
of non Flex Cable
Improper Wiring
from Drive to Motor
Reconnect and Return to Service
Noise
Yes
No
Yes
Return to Service
Return to Factory
No
Yes
No
No
No
No
Yes
Yes
Yes
Yes
Defective
Motor Thermal
Switch
Check Routing
of Cables
Return to Service
Thermal Switch
Resets
No
Return to Factory
Return to Service
Replace Cable
No
Yes
"M" Fault
Motor Over Temperature
Check continuinty of
Motor Feedback cable pin A
Flex cable during test
Disconnect
Motor
Feedback Cable
Disconnect Motor Feedback Cable
at every connection point,
use ohmmeter to check
continuinty of Pin A in cable
If Flex cable try and Flex
Check Continuity pins T to A
of Motor Feedback Connector
MG/NT Motors
shall read short if switch is reset
Replace defective section
or entire Cable
End
End