9
“A” Drive Overtemp
This fault is applicable to the Epsilon Drive only. It is indicated by the display showing
an “A”. If the equipment cabinet that the drive is mounted in has any problem with its
circulation of air or the cooling equipment malfunctions this fault will likely occur.
Potential causes for the “A” Drive Overtemp fault
Sensed temperature in the IGBT (Insulated Gate Bi-polar Transistors a.k.a. Power
Stage) has exceeded 100° Centigrade (212° F).
Noise
“ A” Drive Overtemp”
Notes
Yes
Possible
Noise Problem
Check for
continuity between
Drive Ground and
Motor Ground
with Power Off
Yes
No
No
Drive Resets
Check for
Air Flow Restriction
Air Filters change
if needed
Air Conditioning problems
Ready for Normal
Operation
Cycle Power
to Reset
Check Application
Drive Resets
Remove Power
Allow Cool Down
Approx. 30 minutes
Yes
No
"A" Fault
Drive Overtemp
Epsilon Only
Check Cable Routing and
Spacing between
Feedback and Motor Power
Cable or any other cable with
potential to generate noise
High Ambient
Temperature
in Cabinet
Above 40
o
C
Derate by
3% for every degree
40
o
to 50
o
C max
Contact
Tech Service
End