RSR-2 Troubleshooting Flow Chart
RSR-2
This information is provided for systems equipped with an RSR-2 and an ES Resistor
package. If your system is not configured in such a manner please use this for reference
purposes only.
RSR-2
May potentially
Be Faulty
"H"
Fault
on Drive
Check For
Correct Connection
No
Yes
Normal Operation
Power LED On Steady,
Shunt LEDs On
During Drive
Deceleration Period
Trig In/Trig Out*
Functions
Correctly
Reset
Drive Ready
for Operation
Correct
Wiring
Check
RSR-2
Fuse
Replace if
Open
RSR-2
Fault LED
On
Check Correct Connection
of ES Resistor
R+ and R-, Bus+ ands Bus-,
and PE
Cycle Power to
EN or Epsilon
RSR-2
Configured for
Master/Follower
Disregard
this Flowchart
No
Master
Check Connection
Trig Out to Follower Trig In
Check for
+ 10 to +30 VDC
Between
*DC IN +24 V
and DC IN 0 V
Over Temp
Condition
Detected in
ES Unit
E
xternal
S
hunt
Operated with Over
Temp Sensing
Yes
Yes
Yes
Yes
*Only active if RSR-2
is set up as Master or
Follower device
.
Contact
Tech Support
Seitenansicht 21