Emerson FM-3 Anleitung zur Fehlerbehebung Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
12
“U” Invalid Configuration
This fault is indicated by the display showing a “U”. This display indicates a change in
the physical configuration of the drive. It is not known if setup data in the FM module
matches the current drive and motor attached.
Potential causes for the “U” Invalid configuration fault
FM module not on the drive at previous power up
FM module on the drive at this power up was missing at the prior power up
“U” “Invalid Configuration”
No
"U" Fault
Invalid Configuration
Press and Hold
Drive Reset P/B
for 12 seconds
Display
Changes
to "d"
Yes
Download
Configuration file
Ready for
Normal
Operation
End
FM Module
Present
prior to last
Power Cycle
No Module
Present
prior to last
Power Cycle
Notes
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 59 60

Kommentare zu diesen Handbüchern

Keine Kommentare