Emerson FM-3 Installationshandbuch Seite 170

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 230
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 169
156
FM-3 Programming Module Reference Manual
Wait For – This program instruction halts program execution until the expression becomes
True. Once True, the program continues with the next line of code. The example program
uses a Wait For DriveInput.1 so that the program will wait until DriveInput.1 is activated,
then continue on.
Index.Initiate – This program instruction is used to initiate a single index. When using this
instruction, an Index Selection Box will appear allowing you to select the index you wish to
initiate. This selection box is shown in Figure 21.
Figure 76: Index Selection Box
The program is initiated using DriveInput.4 (see Figure 17).
The setup is now complete, and the example is ready to be downloaded.
Seitenansicht 169
1 2 ... 165 166 167 168 169 170 171 172 173 174 175 ... 229 230

Kommentare zu diesen Handbüchern

Keine Kommentare