Parameter Descriptions
Torque Limit TorqueLimit
This is the level to which the TorqueCommand will be limited when the TorqueLimitEnable
input function is active.
Torque Limit Active TorqueLimitActive
Active when the TorqueCommand is greater than the TorqueLimit and the
TorqueLimitEnable input function is active.
Torque Limit TorqueLimitEnable
This destination is used to enable the TorqueLimit. This is level sensitive.
Travel Limit Minus Activate TravelLimitMinusActivate
This destination is used to activate the travel limit minus fault. It should be assigned to the
travel limit minus sensor. When it is activated the drive will decelerate to a stop using the
deceleration rate defined in the TravelLimitDecel parameter. This is level sensitive.
Travel Limit Plus Activate TravelLimitPlusActivate
This destination is used to activate the travel limit plus fault. It should be assigned to the travel
limit plus sensor. When it is activated the drive will decelerate to a stop using the deceleration
rate defined in the TravelLimitDecel parameter. This is level sensitive.
Travel Limit Deceleration TravelLimitDecel
This parameter defines the ramp used to decelerate the motor to a stop when any travel limit
is activated
Travel Limit Minus Active TravelLimitMinusActive
This source is active when the TravelLimitMinusActivate is active.
Travel Limit Plus Active TravelLimitPlusActive
This source is active when the TravelLimitPlusActivate is active.
Decimal Places TorqueUnits.Decimal
This parameter is the decimal point location for user torque units.