Emerson VSG & VSSG Spezifikationen Seite 29

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 100
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 28
29
Maintenance
Gas Compression "Maintenance and Inspection Schedule"
4/29/2009
R R R R R R R
S S S S S S S S S S S S S
R R R R R R R R R R R R R R
I I I I I I I I I I I I I I
R R R R
I I I I I I I I I I I I I I
I I I I I I I I I I I I I I
I I I I I I I I I I I I I I
I I I I I I I
I
Key: (I) Inspect. (R) Replace. (S) Sample.
(2) Note: The life of the compressor will be increased by purging the compressor unit with dry nitrogen or sweet, dry natural gas at
shutdown.
GROUP
CONTROL
CALIBRATION
120,000
5,000
90,000
100,000
BASED ON DRY CLEAN GAS
50,000
60,000
70,000
200
10,000
20,000
Coalescing Elements
Coupling Alignment
and Integrity
40,000
II
Oil Change
Oil Analysis (1)
Oil Filters
Oil Strainer
INSPECTION
OR
MAINTENANCE
ITEM
COMPRESSOR (2)
RTD's
Inspect Compressor
Bearings
OIL CIRCUIT
PACKAGE
Suction Screen
SERVICE INTERVAL (HOURS)
30,000
110,000
80,000
I I I II I
(1) Note: Oil Analysis/Sampling is based on the gas stream. It is at the customer's discretion to increase the time period between oil
sampling if contamination of oil is unlikely, and to decrease the time period between oil sampling if oil contamination is likely or
evident. An oil sample must be taken when there is reason to believe the oil is contaminated anytime during operation. In landfill,
corrosive, and wet gas conditions, oil sampling is recommended every 3-4 months.
The life of the oil is directly affected by the quality of the gas. Proper separation of any liquids must be accomplished to prevent
droplets of liquid at the compressor suction. The discharge temperature of the compressor must be kept a minimum of 30°F above
the discharge gas dew point to prevent the condensing of liquids in the oil separator. The oil separator shell and legs must be
insulated when the gas stream has a high probability of having condensables.
I II I I I
Transducers
NOTE: See Motor Manual for proper lubrication procedures and service intervals.
Gas Compression Maintenance and Inspection Schedule
Seitenansicht 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 99 100

Kommentare zu diesen Handbüchern

Keine Kommentare