Table 1. Specifica tions
Valve Body Sizes and End Connection Styles
(1)
See table 2
Maximum Inlet Pressures and Temperatures
(1)
If the valve nameplate shows an ASME
pressure-temperature class, maximum inlet pressure
and temperature is consistent with the applicable
class per ASME B16.34. If the nameplate does not
show an ASME class, it will show a maximum cold
working pressure at 38_C(100_F) (for example, 293
bar [4250 psi])
Maximum Pressure Drops
(1)
See table 4
Shutoff Classification per ANSI/FCI 70-2
and IEC 60534-4
Class IV
Material Temperature Capabilities
(1)
Valve Body Assembly:
Standard Bonnet O-Ring: -40 to 135C(-40to275F)
Optional Fluorocarbon Bonnet O-Ring: -23 to 204C
(-10 to 400F)
Flow Characteristic
Equal percentage
Flow Direction
Flow up only
Port Diameters
See table 2
Valve Plug Travel
19 mm (0.75 inch)
Valve Plug Style
Micro-Form valve plug
Available ActuatorConfigurations
On/off (snap acting)
Positioning (flow or pressure control)
Power Requirements
12 or 24VDC, minimum 4 amp power supply required
(fuse to 5 amps)
Maximum Current Draw
4amps
Idle Current Draw
38 mA
Conduit Connections
Two 3/4 NPT connections
Stroke Length
19mm (0.75 inch)
Nominal Stroke Speed
(2)
3.9 mm/s (0.15 inch/s) at 24 VDC
2.2 mm/s (0.09 inch/s) at 12 VDC
Hazardous Area Approvals
CSA (C/US): ExplosionProof Class I, Division 1,
GroupsCandD,T6,ExdIIAT6,ClassI,Zone1,AExd
IIA T6
ATEX Flameproof - Gas:
II 2 G ,Ex d IIA T6
IECEx Flameproof - Gas: Ex d IIA T6
Enclosure Rating
Type 4X and IP66
Duty Cycle
50% maximum
Enclosure M aterial
Cast aluminum alloy with powder coat paint
Approximate Weight:
22 - 51 kg (49 - 113 lbs), depending upon
construction
1. The pressure or temperature limits in the referenced tables and a ny applicable ASME code limitations should not be exceeded.
2. 10% variation can be expected, based on temperature and pressure of application.