Reference Manual
00809-0200-4801, Rev CA
July 2010
Rosemount 3051S
B-36
Hardware Adjustments
Standard Standard
D1
(14)(18)(19)
Hardware adjustments (zero, span, alarm, security) ★
Process Adapters
Standard Standard
D2
(17) 1
/2-14 NPT process adapters ★
Expanded
D9
(17)
RC
1
/2 SST process adapters
Custody Transfer
Standard Standard
D3
(20)
Measurement Canada Accuracy Approval ★
External Ground Screw Assembly
Standard Standard
D4 External ground screw assembly ★
Drain/Vent Valve
Standard Standard
D5
(17)
Delete transmitter drain/vent valves (install plugs) ★
Expanded
D7
(17)
Coplanar flange without drain/vent ports
Conduit Plug
Standard Standard
DO
(21)
316 SST Conduit Plug ★
Product Certifications
(22)
Standard Standard
E1 ATEX Flameproof ★
I1 ATEX Intrinsic Safety ★
IA ATEX FISCO Intrinsic Safety (FOUNDATION
™
fieldbus protocol only) ★
N1 ATEX Type n ★
K1 ATEX Flameproof, Intrinsic Safety, Type n, Dust ★
ND ATEX Dust ★
E4 TIIS Flameproof ★
I4
(23)
TIIS Intrinsic Safety ★
E5 FM Explosion-proof, Dust Ignition-proof ★
I5 FM Intrinsically Safe, Division 2 ★
IE FM FISCO Intrinsically Safe (FOUNDATION
™
fieldbus protocol only) ★
K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★
E6
(24)
CSA Explosion-proof, Dust Ignition-proof, Division 2 ★
I6 CSA Intrinsically Safe ★
IF CSA FISCO Intrinsically Safe (FOUNDATION
™
fieldbus protocol only) ★
K6
(24)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★
E7 IECEx Flameproof, Dust Ignition-proof ★
I7 IECEx Intrinsic Safety ★
IG IECEx FISCO Intrinsic Safety (FOUNDATION
™
fieldbus protocol only) ★
N7 IECEx Type n ★
K7 IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n ★
E2 INMETRO Flameproof ★
I2 INMETRO Intrinsic Safety ★
K2 INMETRO Flameproof, Intrinsic Safety ★
E3 China Flameproof ★
I3 China Intrinsic Safety ★
KA
(24)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2 ★
KB
(24)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★
KC FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 ★
KD
(24)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe ★
Sensor Fill Fluid
Standard Standard
L1
(25)
Inert sensor fill fluid ★
Table B-1. 3051S Series Coplanar Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.