Reference Manual
00809-0200-4801, Rev CA
July 2010
Rosemount 3051S
B-30
Figure B-10. Rosemount
3051SFP Integral Orifice
Flowmeter
Rosemount 3051SFP Integral Orifice Flowmeter
Front View
Bottom View Side View
Dimensions are in inches (millimeters)
Line Size
Dimension
1
/2-in. (15 mm) 1-in. (25 mm) 1
1
/2-in. (40 mm)
J (Beveled/Threaded pipe ends) 12.54 (318.4) 20.24 (514.0) 28.44 (722.4)
J (RF slip-on, RTJ slip-on, RF-DIN slip on) 12.62 (320.4) 20.32 (516.0) 28.52 (724.4)
J (RF 150#, weld neck) 14.37 (364.9) 22.37 (568.1) 30.82 (782.9)
J (RF 300#, weld neck) 14.56 (369.8) 22.63 (574.7) 31.06 (789.0)
J (RF 600#, weld neck) 14.81 (376.0) 22.88 (581.0) 31.38 (797.1)
K (Beveled/Threaded pipe ends) 5.74 (145.7) 8.75 (222.2) 11.91 (302.6)
K (RF slip-on, RTJ slip-on, RF-DIN slip on)
(1)
5.82 (147.8) 8.83 (224.2) 11.99 (304.6)
K (RF 150#, weld neck) 7.57 (192.3) 10.88 (276.3) 14.29 (363.1)
K (RF 300#, weld neck) 7.76 (197.1) 11.14 (282.9) 14.53 (369.2)
(1) Downstream length shown here includes plate thickness of 0.162-in. (4.11 mm).
Flow
8.8 (223.46)
J Upstream
K
(1)
Downstream
5.3
(134.14)
11.9
(302.3)
7.7 (195.6)
B.D.