Seitenansicht 148
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
149
Table 7-33 Sensor No. 25 FanFault Z2F3
Feature Raw Value/Description Interpreted Value
Sensor Name FanFault Z2F3
Type of Measurement
Class 0x03 Discrete
Sensor Type 0xC0 OEM-reserved
Sensor Owner LUN 0x00
Entity ID 0x0A
Entity Instance 0x60
Rearm mode Auto
Event message control Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x02, 0x00
Deassertion Event Mask (bytes
17,18)
0x02, 0x00
Discrete Reading Mask (bytes
19, 20)
0x03, 0x00 Supports 2 States
Reading Definition Assertion signals a fan controller fault
Table 7-34 Sensor No. 26 FuseFail 48VA1
Feature Raw Value/Description Interpreted Value
Sensor Name FuseFail 48VA1
Type of Measurement
Class 0x03 Discrete
Sensor Type 0xC0 OEM-reserved
Sensor Owner LUN 0x00
Entity ID 0x0A
Entity Instance 0x60
Rearm mode Auto
Event message control Entire Sensor only
Seitenansicht 148