FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
126
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xDB, 0xDA, 0xD9 (11.8260, 11.7720, 11.7180) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xF7, 0xF9, 0xFA (13.3380, 13.4460, 13.5) Volts
Table 7-3 Sensor No. 4 +12V B_MON
Feature Raw Value/Description Interpreted Value
Sensor Name +12V B_MON
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Table 7-2 Sensor No. 3 +12V A_MON (continued)
Feature Raw Value/Description Interpreted Value