Emerson 1410 Wartungshandbuch Seite 136

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 222
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 135
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
136
Table 7-16 Sensor No. 11 Fan 4
Feature Raw Value/Description Interpreted Value
Sensor Name Fan 4
Device
Sensor Type 0x04 Fan
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x1D Cooling Unit
Entity Instance 0x63
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F3F Upper and Lower Non-Critical, Critical
and Non-Recoverable Thresholds are
Readable and Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0x24, 0x24, 0x24 (1224, 1228, 1224) RPM
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xCE, 0xE6, 0xF2 (7004, 7820, 8228) RPM
Table 7-17 Sensor No. 12 Fan 5
Feature Raw Value/Description Interpreted Value
Sensor Name Fan 5
Device
Sensor Type 0x04 Fan
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x1D Cooling Unit
Seitenansicht 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 221 222

Kommentare zu diesen Handbüchern

Keine Kommentare