Emerson Y695VR Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Nein Emerson Y695VR herunter. Emerson Y695VR Instruction Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Y695VR Series
D102598X012
Instruction Manual
Form 5467
December 2008
www.emersonprocess.com/regulators
Y695VR Series Vacuum Regulators
Introduction
Scope of Manual
This manual describes and provides instructions
and parts lists for the Types Y695VR and Y695VRM
vacuum regulators. Instructions and parts lists for
other equipment used with these regulators are found
in separate manuals.
Product Description
The Y695VR Series vacuum regulators are used for
precise control of small capacity, low-pressure service
applications where an increase in vacuum must be
limited. These direct-operated vacuum regulators
come in 3/4 and 1-inch (DN 20 and 25) body sizes
and have a 7/16-inch (11,1 mm) orice and a 1/4-inch
spring case vent connection with optional umbrella
vent assembly. The individual products are described
as follows:
Type Y695VR
The Type Y695VR is a vacuum regulator with internal
pressure registration requiring no downstream
control line.
Type Y695VRM
The Type Y695VRM is a vacuum regulator with
external registration. The throat is blocked with an
O-ring stem seal.
Specications
Specications for the Y695VR Series vacuum
regulators are listed on page 2. Specications for a
given regulator as it originally comes from the factory
are stamped on the nameplate.
W7295
Figure 1. Type Y695VR Vacuum Regulator
Installation
Personal injury, property damage,
equipment damage, or leakage due to
escaping gas or bursting of pressure-
containing parts may result if this
equipment is overpressured or is
installed where service conditions
could exceed the limits given in the
Specications, or where conditions
exceed any ratings of the adjacent
piping or piping connections. To
avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation, or standard) to prevent
service conditions from exceeding
those limits. Additionally, physical
damage to this equipment could cause
personal injury or property damage due
to escaping gas. To avoid such injury or
damage, install the equipment in a safe
and well ventilated location.
!
WARNING
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Y695VR Series

Y695VR SeriesD102598X012Instruction ManualForm 5467December 2008www.emersonprocess.com/regulatorsY695VR Series Vacuum RegulatorsIntroductionScope of M

Seite 2

Y695VR Series2CONTROL PRESSURE (VACUUM)OUTLET PRESSURE (VACUUM)ATMOSPHERIC PRESSUREB2582VACUUM BEINGCONTROLLEDHIGHERVACUUM SOURCEVACUUMPUMPSpecicatio

Seite 3

Y695VR Series3!WARNING!WARNINGEquipment operation within ratings does not preclude the possibility of damage from debris in the lines or from external

Seite 4

Y695VR Series4 4. Remove and inspect the body seal O-ring (key 11). For a Type Y690VBM, also inspect the throat seal O-ring (key 31) by remo

Seite 5

Y695VR Series5Table 1. Vacuum Control Pressure Ranges and Spring Part Numbers (Spring, Key 6) VACUUM CONTROL PRESSURE RANGESPRING PART NUMBERSPRING C

Seite 6

Y695VR Series6Table 2. Body Part Numbers (Key 1)BODY MATERIAL END CONNECTION STYLE(1)PART NUMBER3/4-Inch (DN 20) Body 1-Inch (DN 25) BodyDuctile iron

Seite 7

Y695VR Series7B2677_2Figure 3. Type Y695VR AssemblyB2677_1

Seite 8

Y695VR Series©Emerson Process Management Regulator Technologies, Inc., 1999, 2008; All Rights ReservedThe Emerson logo is a trademark and service mark