12 Modbus
®
Mapping Assignments for Micro Motion
®
Transmitters
Modbus Mapping Assignments continued
3 0422 Bit #0 API: Temperature outside standard range
ÖÖÖ
Bit #1 API: Density outside standard range
ÖÖÖ
Bit #2 Line temperature sensor out of range
ÖÖÖ
Bit #3 Meter temperature sensor out of range
ÖÖÖ
Bit #4 Flow direction (1 = reverse, 0 = forward or zero flow)
ÖÖÖ
Bit #5 Not used
Bit #6 Not used
Bit #7 Not used
Bit #8 Not used
Bit #9 Transmitter not configured
ÖÖÖ
Bit #10 (E)EPROM checksum error
ÖÖ
Bit #11 RAM test error in transmitter
ÖÖ
Bit #12 Invalid/unrecognized sensor type
ÖÖÖ
Bit #13 (E)EPROM database corrupt
ÖÖÖ
Bit #14 (E)EPROM powerdown totals corrupt
ÖÖÖ
Bit #15 (E)EPROM program corrupt
ÖÖÖ
3 0423 Bit #0 Boot sector fault
ÖÖÖ
Bit #1 Software upgrade needed
ÖÖ
Bit #2 Frequency output fixed
ÖÖ
Bit #3 Not used
Bit #4 DO1 status (0=OFF, 1=ON)
ÖÖ
Bit #5 DO2 status (0=OFF, 1=ON)
6
Ö
Bit #6 T-Series D3 calibration in progress
ÖÖÖ
Bit #7 T-Series D4 calibration in progress
ÖÖÖ
Bit #8 Not used
Bit #9 Not used
Bit #10 Temperature slope calibration in progress
ÖÖÖ
Bit #11 Temperature offset calibration in progress
ÖÖÖ
Bit #12 Flowing density calibration in progress
ÖÖÖ
Bit #13 High-density calibration in progress
ÖÖÖ
Bit #14 Low-density calibration in progress
ÖÖÖ
Bit #15 Flowmeter zeroing in progress
ÖÖÖ
3 0424 Bit #0 Discrete input 1 status (0=OFF, 1=ON)
4
Ö
Bit #1 Not used
Bit #2 Discrete output 1 fixed
ÖÖ
Bit #3 Discrete output 2 fixed
4
Ö
Bit #4 Not used
Bit #5 Not used
Bit #6 Security breach
Ö
Bit #7 Not used
Bit #8 Not used
Bit #9 Not used
Bit #10 Not used
Bit #11 Not used
Bit #12 Not used
Bit #13 Not used
Bit #14 Not used
Bit #15 Not used
Table 2-5. Input registers continued
Address Description MVDSolo
Series
1000
Series
2000 RFT9739