4 Modbus
®
Mapping Assignments for Micro Motion
®
Transmitters
Modbus Mapping Assignments continued
Table 2-2. RFT9739 security coils
Address Description RFT9739
0 0113 Read protect calibration factors
Ö
0 0114 Write protect output variables and units
Ö
0 0115 Write protect scaled integers
Ö
0 0116 Write protect sensor and transmitter information
Ö
0 0117 Write protect special units factors
Ö
0 0118 Write protect control output variable
Ö
0 0119 Write protect flow direction
Ö
0 0120 Write protect fault code
Ö
0 0121 Write protect fault limit
Ö
0 0122 Write protect output variables
Ö
0 0123 Write protect flowmeter zeroing and process variable limits
Ö
0 0124 Write protect pressure variables
Ö
0 0125 Write protect calibration factors
Ö
0 0126 Write protect coil 00002 (start/stop totalizer)
Ö
0 0127 Write protect coil 00003 (reset totals)
Ö
0 0128 Write protect coil 00004 (reset inventories)
Ö
0 0129 Write protect coil 00005 (perform flowmeter zeroing)
Ö
0 0130 Write protect coil 00006 (trim primary mA output at 4 mA or 0 mA)
Ö
0 0131 Write protect coil 00007 (trim primary mA output at 20 mA)
Ö
0 0132 Write protect coil 00008
(trim secondary mA output at 4 mA or 0 mA)
Ö
0 0133 Write protect coil 00009 (trim secondary mA output at 20 mA)
Ö
0 0134 Write protect coil 00010 (fix primary mA output)
Ö
0 0135 Write protect coil 00011 (fix secondary mA output)
Ö
0 0136 Write protect coil 00012 (fix frequency output)
Ö
0 0137 Write protect coil 00013 (perform low-density calibration)
Ö
0 0138 Write protect coil 00014 (perform high-density calibration)
Ö
0 0142 Write protect coil 00018 (save non-volatile data)
Ö
0 0143 Read/write protect master reset defaults
Ö
0 0144 Read/write protect coil 00020 (perform transmitter self-test)
Ö
0 0145 Read protect coil 10021 (EEPROM checksum failure)
Ö
0 0146 Read protect coil 10022 (RAM diagnostic failure)
Ö
0 0147 Read protect coil 10023 (real-time interrupt failure)
Ö
0 0148 Read protect coil 10024 (sensor failure)
Ö
0 0149 Read protect coil 10025 (temperature sensor failure)
Ö
0 0150 Read protect coil 10026 (flowmeter zeroing failure)
Ö
0 0151 Read protect coil 10027 (other failure occurred)
Ö
0 0152 Read protect coil 10028 (transmitter initializing/warming up)
Ö
0 0153 Read protect coil 10029 (primary variable out of range)
Ö
0 0154 Read protect coil 10030 (non-primary variable out of range)
Ö
0 0155 Read protect coil 10031 (milliamp output saturated)
Ö
0 0156 Read protect coil 10032 (milliamp output fixed)
Ö
0 0157 Read protect coil 10033 (watchdog timer error)
Ö
0 0158 Read protect coil 10034 (power reset occurred)
Ö
0 0159 Read protect coil 10035 (transmitter configuration changed)
Ö
0 0160 Read protect coil 10036 (transmitter electronics failure)
Ö