5
MAIN VALVE BODY SIZE
MAIN VALVE
BODY MATERIAL
END CONNECTION STYLE
(2)
STRUCTURAL DESIGN
RATING
(3)
MAXIMUM OPERATING
INLET PRESSURE
(3)
In. DN psig bar psig bar
1, 2, 3 and 4 25, 50, 80 and 100
WCC Steel
NPT or SWE
(1 and 2 in. only)
1500 103 300 20.7
CL150 RF 290 20.0 290 20.0
CL300 RF 750 51.7
300 20.7
CL600 RF 1500 103
PN 16/25/40 RF
(4)
580 40.0
CF8M Stainless steel
NPT
(1 and 2 in. only)
1440 99.2 300 20.7
CL150 RF 275 19.0 275 19.0
CL300 RF 720 49.6
300 20.7CL600 RF 1440 99.2
PN 16/25/40 RF
(4)
580 40.0
1. The pressure/temperature limits in this Bulletin and any applicable standard or code limitation should not be exceeded.
2. Ratings and end connections for other than ASME standard can usually be provided. Contact your local Sales Ofce for assistance.
3. Maximum cold working pressure (CWP) per ASME B16.34 or product Bulletin limit, whichever is lowest. Temperature may decrease these maximum pressures.
4. Not available for 4 in. / DN 100 body size.
Table 1. Type LR125 Main Valve Body Sizes, End Connection Styles, Structural Design Ratings and Maximum Operating
Inlet Pressures
(1)
Installation
The robust design of the Type LR125 allows this regulator
to be installed indoors or outdoors. This regulator
is designed to withstand the elements. The powder
paint coating protects regulator against minor impacts,
abrasions and corrosion. When installed outdoors,
the Type LR125 does not require protective housing.
However, the Type MR95H pilot should be oriented so
that the pilot spring case vent is pointed down. Otherwise,
make sure the vent is protected so that rain, moisture,
insects or any debris will not accumulate inside or block
the vent assembly.
When installed indoors, install remote
venting of the pilot spring case as required by applicable
codes and regulations.
Table 3. Outlet (Control) Pressure Ranges
PILOT
OUTLET PRESSURE RANGE SPRING WIRE DIAMETER SPRING FREE LENGTH
SPRING PART NUMBER
AND COLOR
psig bar In. mm In. mm
Type MR95H
15 to 30
25 to 75
70 to 150
1.0 to 2.1
1.7 to 5.2
4.8 to 10.3
0.207
0.234
0.283
5.26
5.94
7.19
2.50
2.60
2.44
63.5
65.9
62.0
ERCA04288A0 Yellow
ERAA01910A0 Green
ERAA01911A0 Red
Table 2. Type MR95H Pilot Maximum Cold Working Pressure
(1)(2)
17E68 NITRILE (NBR) 17E97 NITRILE (NBR) 17E88 FLUOROCARBON (FKM)
Liquid Temperature -20 to 150°F / -29 to 66°C 0 to 150°F / -18 to 66°C 0 to 250°F / -18 to 121°C
(1)
General Applications
Best for low pressure
differential and cold temperature
service applications.
Best for abrasive or
erosive service applications.
Best for high temperature
applications.
Heavy Particle Erosion Fair Excellent Good
1. Fluorocarbon (FKM) is limited to 200°F / 93°C in hot water.
Table 4. Diaphragm Material Selection Information
BODY SIZE BODY AND SPRING CASE MATERIAL MAXIMUM INLET PRESSURE MAXIMUM OUTLET PRESSURE
1/2 NPT
Steel
Stainless steel
300 psig / 20.7 bar
300 psig / 20.7 bar
300 psig / 20.7 bar
300 psig / 20.7 bar
1. The pressure/temperature limits in this Bulletin, and any applicable standard or code limitation should not be exceeded.
2. Temperature and/or the body end connection may decrease these maximum pressures.
Overpressure Protection
Overpressuring any portion of a regulator or associated
equipment may cause personal injury, leakage
or property damage due to bursting of pressure-
containing parts. Provide appropriate pressure relieving
or pressure limiting devices to ensure that the limits in
the Specications section are not exceeded. Common
methods of external overpressure protection include
relief valves, monitoring regulators, shutoff devices
and series regulation. Regulator operation within
ratings does not prevent the possibility of damage from
external sources or from debris in the pipeline. Install
additional strainer or lter upstream of the regulator for
applications with high levels of debris.