Product Data Sheet
00813-0100-4530, Rev AA
Catalog 2008 - 2009
Rosemount 5300 Series
Level-38
Code Hazardous Locations Certifications
NA No Hazardous Locations Certifications
E1 ATEX Flameproof
E5 FM Explosion Proof
E6 CSA Explosion Proof
E7 IECEx Flameproof
I1 ATEX Intrinsic Safety
IA ATEX FISCO Intrinsic Safety
(6)
I5 FM Intrinsic Safety and Non-Incendive
IE FM FISCO Intrinsic Safety
(6)
I6 CSA Intrinsic Safety
IF CSA FISCO Intrinsic Safety
(6)
I7 IECEx Intrinsic Safety
IG IECEx FISCO Intrinsic Safety
(6)
KA ATEX, FM, CSA Flameproof/Explosionproof
KB ATEX, FM, IECEx Flameproof/Explosionproof
KC ATEX, CSA, IECEx Flameproof/Explosionproof
KD FM, CSA, IECEx Flameproof/Explosionproof
KE ATEX, FM, CSA Intrinsic Safety
KF ATEX, FM, IECEx Intrinsic Safety
KG ATEX, CSA, IECEx Intrinsic Safety
KH FM, CSA, IECEx Intrinsic Safety
KI FISCO - ATEX, FM, CSA Intrinsic Safety
(6)
KJ FISCO - ATEX, FM, IECEX Intrinsic Safety
(6)
KK FISCO - ATEX, CSA, IECEX Intrinsic Safety
(6)
KL FISCO - FM, CSA, IECEX Intrinsic Safety
(6)
Code Options
M1 Integral digital display
P1 Hydrostatic testing
(7)
LS Long stud 9.8 in (250 mm) for flex. single lead probe to prevent contact with wall/nozzle.
Standard height is 3.9 in (100 mm) for probes 5A and 5B; 5.9 in. (150 mm) for probes 6A and 6B.
T1 Transient Protection Terminal Block (standard with FISCO options)
Cx - Special Configuration (Software)
C1 Factory configuration (CDS required with order)
C4 Namur alarm and saturation levels, high alarm
C5 Namur alarm and saturation levels, low alarm
C8 Low alarm
(8)
(standard Rosemount alarm and saturation levels)
Qx - Special Certifications
Q4 Calibration Data Certification
Q8 Material Traceability Certification per EN 10204 3.1
(9)
(1) Not available with Flame/Explosionproof approvals (E1, E5, E6, E7, KA, KB, KC, and KD)
(2) Process seal rating. Final rating depends on flange and O-ring selection. See “Tank Connection” on page 7.
(3) For other materials, consult factory.
(4) Extra length for fastening is added in factory.
(5) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit.
If tank height is unknown, please round up to an even length when ordering. Probes can be cut to exact length in field. Maximum allowable length is
determined by process conditions. See “Mechanical Considerations” on page 15 for more probe length guidance.
(6) Requires Foundation™ fieldbus signal output (U
i
parameter listed in “Product Certifications” on page 21).
(7) Available for flanged connection.
(8) The standard alarm setting is high.
(9) Certificate includes all pressure retaining wetted parts.
Example Model String: 5303-H-A-1-S-1-V-6A-M-025-50-AA-I1-M1C1. E-025-05, means 25 ft and 5 in. probe length. M-025-50, means 25.5 m.