Bulletin 71.3:Y692VB
3
INLET PRESSURE
CONTROL PRESSURE (VACUUM)
ATMOSPHERIC PRESSURE
Type Y692VB
B2579
VACUUM
BEING LIMITED
VACUUM
PUMP
Figure 2. Type Y692VB Operational Schematic
INLET PRESSURE
CONTROL PRESSURE (VACUUM)
ATMOSPHERIC PRESSURE
Type Y692VB
B2579
VACUUM
BEING LIMITED
VACUUM
PUMP
An increase in vacuum (decrease in absolute pressure)
beyond the setpoint registers on the diaphragm,
opening the disk. This permits body inlet pressure to
enter the system and restore the controlled vacuum
to the setpoint. On the Type Y692VB, the pressure
at the regulator body outlet registers directly into the
diaphragm casing. The Type Y692VBM has a control
line connecting the diaphragm casing to the vacuum
being controlled and an O-ring stem seal blocking the
throat allowing for registration only through the control
line connection (outlet body pressure may or may not
be the same as the pressure in the diaphragm casing).
Installation
The versatility of the Y692VB Series vacuum breakers
permits a wide variety of installations. The body may
be mounted in any position (360° rotation possible)
relative to the spring and diaphragm cases by loosening
the union nut and rotating the diaphragm casing. The
spring case can be rotated to t the orientation required.
Any mounting position provides excellent performance.
When exposed to the weather, the spring case port
should be protected by an optional umbrella vent or
should be pointed downward to allow condensate to
drain. On indoor installations, this port should be piped
outdoors if used in hazardous gas service.