Type T205B
3
When pressure in the tank increases, the actuator
diaphragm is pushed. Through the action of the pusher
post assembly, lever and valve stem, the valve disk
moves closer to the orice reducing gas ow.
The regulator plug is balanced (inlet pressure
creates equal upward and downward forces on these
components) see Figure 4, therefore, the outlet
(control) pressure of the unit is not affected by inlet
pressure variation.
Principle of Operation
Refer to Figure 2. Type T205B tank blanketing
regulator controls the vapor space pressure over a
stored liquid. When liquid is pumped out of the tank or
vapors in the tank condense, the pressure in the tank
decreases. Tank pressure is sensed by the actuator
diaphragm. Spring force pushes the pusher post
assembly, the valve disk moves away from the orice,
allowing the gas ow to increase.
Type T205B Tank Blanketing Regulator
MXXXX
November 2012
Type T205B
INLET PRESSURE
OUTLET PRESSURE
ATMOSPHERIC PRESSURE
ORIFICE
BALANCED TRIM
ASSEMBLY
VALVE DISK
CONTROL SPRING
LEVER
PUSHER POST
PRESSURE
REGISTRATION
DIAPHRAGM
TYPE Y602-1 VENT
Figure 2. Type T205B Operational Schematic
HORIZONTAL PIPELINE
VENT POINTED DOWN
DOWNSTREAM CONTROL LINE
INLET PRESSURE
OUTLET PRESSURE
ATMOSPHERIC PRESSURE
LOADING PRESSURE