S201 and S202 Series
D400007X012
Instruction Manual
Form 5171
October 2009
www.emersonprocess.com/regulators
S201 and S202 Series Gas Regulators
Fisher
®
regulators must be installed,
operated, and maintained in accordance
with federal, state, and local codes, rules
and regulations, and Emerson Process
Management Regulator Technologies,
Inc., instructions.
For LP-Gas service, an approved
regulator (such as one listed by U.L.)
should be used. The installation,
in most states, must comply with
NFPA standards.
If the regulator vents gas or a leak
develops in the system, service to
the unit may be required. Failure
to correct trouble could result in a
hazardous condition.
Call a gas service person to service
the unit. Only a qualied person must
install or service the regulator.
!
WARNING
Figure 1. Typical S200 Gas Regulator
W1919
Introduction
Scope of the Manual
This instruction manual provides instructions for
installation, adjustment, maintenance, and parts
ordering information for Types S201, S201H, S201K,
S202, and S202H gas service regulators.
Description
S201 and S202 Series regulators are typically
installed on industrial and commercial applications.
The Types S202 and S202H regulators contain an
internal relief valve. Units with an “H” or “K” sufx
are similar to the basic regulators but deliver a higher
outlet pressure of 1 to 5 psig (69 mbar to 0,35 bar) and
2 to 10 psig (0,14 to 0,69 bar), respectively.
Specications
The Specications section lists the specications for
the regulators. The following information is stamped
on the regulator at the factory: type number, date of
manufacture, spring range, orice size, maximum inlet
pressure, maximum operating outlet pressure, and
outlet pressure which may damage regulator parts.
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - S201 and S202 Series

S201 and S202 SeriesD400007X012Instruction ManualForm 5171October 2009www.emersonprocess.com/regulatorsS201 and S202 Series Gas RegulatorsFisher® regu

Seite 2

S201 and S202 Series2SpecicationsPrinciple of OperationRefer to Figure 2. When downstream demand decreases, the pressure under the diaphragm increas

Seite 3

S201 and S202 Series3Figure 4. Type S201 Regulator Installed with the Vent Pointed Downward and with a Type 289H Relief Valve for High Capacity Relie

Seite 4

S201 and S202 Series4Before installing the regulator, check for damage which might have occurred in shipment. Also check for dirt or foreign matter w

Seite 5

S201 and S202 Series5 1. Check to see that all appliances are turned off. 2. Slowly open the upstream block valve. 3. Check inlet and outlet pre

Seite 6

S201 and S202 Series6Parts ListKey Description Part Number Spare Parts (Repair Parts Kit includes keys 5, 7, 16, and 19)

Seite 7

S201 and S202 Series7Figure 5. Type S202 Regulator Assembly50A9455PARTS NOT SHOWN: 46 APPLY LUB/SEA/ADHSECTION A-AAAVENT6261585560565759184532689

Seite 8

S201 and S202 SeriesThe Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective own

Kommentare zu diesen Handbüchern

Keine Kommentare