Emerson Micro Motion Transmitters and Discrete Controllers Series 3000 Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10 Micro Motion
®
Series 3000 Transmitters and Controllers
Hazardous area classifications
Model 3100 accessory
UL is a U.S.A. approvals agency. CSA is a Canadian approvals agency that provides approvals accepted in both the U.S.A.
(C-US) and Canada. ATEX is a European directive.
UL and CSA Model 3300 Class I, Div. 2, Groups A, B, C, and D when installed in a suitable
enclosure
Model 3350 Class I, Div. 2, Groups A, B, C, and D
Model 3500 Class I, Div. 2, Groups A, B, C, and D when installed in a suitable
enclosure
Provides non-incendive sensor outputs for use in Class I, Div. 2,
Groups A, B, C, and D, or intrinsically safe sensor outputs for use
in Class I, Div. 1, Groups C and D; Class II, Div. 1, Groups E, F,
and G
Model 3700 Class I, Div. 2, Groups A, B, C, and D
Provides non-incendive sensor outputs for use in Class I, Div. 2,
Groups A, B, C, and D, or intrinsically safe sensor outputs for use
in Class I, Div. 1, Groups C and D; Class II, Div. 1, Groups E, F,
and G
ATEX Model 3350 ATEX Zone 1
CE 0575 II 2G Ex de [ib] IIB/IIC T4 Gb
Model 3500 Safe area only. Can be connected to a sensor in ATEX Zone 1
area.
CE 0575 II (2)G [Ex ib] IIB/IIC
Model 3700 ATEX Zone 1
CE 0575 II 2G Ex de [ib] IIB/IIC T4 Gb
Relays module Three relays
Solid state, SPST
Rated at 24–250 VAC, 40 mA to 5 A; or 0–70 VDC, 5 A
Energized by discrete outputs
NEMA 4X (IP65) enclosure (optional)
UL and CSA approvals Class I, Div. 2, Groups A, B, C, and D
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 23 24

Kommentare zu diesen Handbüchern

Keine Kommentare