Changing the LED Channel Configurations
The LED channel configurations can be changed by using the commands CONFIG. The command CONFIG is also described in
"Commands" of the User Instructions (Section 5847). Section 5847 can be accessed via the CD (Electronic Documentation Package)
furnished with your system. The command, when entered, will display a header that contains the current configuration. Then,
individually, the command will list each item that can be changed, showing the current information, and then prompting for new or
revised information to be entered. If the current information does not need to be changed, press
ENTER to continue.
Command CONFIG: If the command CONFIG is entered, the system will ask that you identify which channel you wish to modify. Another
way of entering the command is to identify the desired channel in the command line by typing the channel number after the characters
CONFIG (ex. CONFIG L1). The various information pertaining to an LED Channel that can be changed through this command is described
below. This command is available to users programmed for access to level 6 commands.
Note:
Parameters which apply only to TL1 commands/messages do not appear for configuration if the TL1 software option is not installed.
Type
, then press
.
Channel active (Y or N)
If "Y" is entered, the system will
allow the default configuration
information of the current LED
channel to be changed as shown
below.
Type
if the channel is required to be active and
if not, then press
.
If "N" was entered above, the system
responds with...
Set channel configuration to
default values? (Y or N):
Type
to change the attributes of this channel to their default values.
If ”Y” is entered, this command terminates.
If ”N” is entered, the system will allow the default configuration
information of the current LED channel to be changed as shown below.
Name:
Type the desired name for this LED channel (30 characters maximum),
then press
.
Color (Red, Green, or Amber):
Type
,
, or
to specify the color the LED illuminates, then
press
.
Sub-access Identifier:
This parameter applies only to TL1 commands/messages. Type the
name (20 characters maximum) of the sub-access identifier that this
channel belongs to, then press
. The group of LMS1000 channels
monitoring a sub-entity in an NMA system should have the same
access identifier and sub-access identifier. Only alpha-numeric
characters can be entered for this parameter. TL1 uses specific values
for this parameter. Refer to TA-NWT-001360, Table 4-1.
Alarm Type (Y or N):
Type
if the alarm condition determined by this channel is required to
be recorded in the alarm log (required if System Alarm Reporting is
desired for this channel, and/or an alarm class of 1 through 8 is
assigned to this channel) when it is activated and
if not, then press
.
If "Y" was entered above, the
system responds with...
System Alarm Report mode (Y or
Type
if the system is required to initiate an alarm report via phone
lines if this channel alarms and
if not, then press
.
If "Y" was entered above for "Alarm
Type", the system responds with...
Type the desired alarm class number associated with this channel, then
press
. Alarm classes are specified with the numbers 0 through 8,
with 0 representing no alarm class.