www.Fisher.comFisherr V500 Rotary Control ValveThe Fisher V500 eccentric plug rotary control valvecontrols erosive, coking, and other hard-to-handlefl
V500 ValveD100054X012Product Bulletin51.3:V500May 201210Table 7. Maximum Allowable Shutoff Pressure Drops for Level 4 Trim(1)VALVE BODYMATERIALBEARING
V500 ValveD100054X012Product Bulletin51.3:V500May 201211Table 8. Material Temperature Capabilities(1)PART NAME MATERIALMINIMUM TO MAXIMUM TEMPERATURE_
V500 ValveD100054X012Product Bulletin51.3:V500May 201212Table 9. Material Combinations(1)TrimLevelPlug Seat Ring Retainer Valve Shaft Bearing O-Ring B
V500 ValveD100054X012Product Bulletin51.3:V500May 201213Table 10. Actuator Mounting Selections, with Actionand Open Plug Position OptionsMOUNTING ACTI
V500 ValveD100054X012Product Bulletin51.3:V500May 201214Table 11. Fisher V500 Rotary Control Flanged and Flangeless Valve DimensionsVALVESIZE,NPSDIMEN
V500 ValveD100054X012Product Bulletin51.3:V500May 201215CoefficientsTable 12. Fisher V500, Forward Flow, Level 1, 2 and 3 Trims Full PortCoefficientsV
V500 ValveD100054X012Product Bulletin51.3:V500May 201216Table 13. Fisher V500, Reverse Flow, Level 1, 2, and 3 Trims Full PortCoefficientsValveSize,NP
V500 ValveD100054X012Product Bulletin51.3:V500May 201217Table 14. Fisher V500, Forward Flow, Level 1, 2, and 3 Trims Reduced PortCoefficientsValveSize
V500 ValveD100054X012Product Bulletin51.3:V500May 201218Table 15. Fisher V500, Reverse Flow, Level 1, 2, and 3 Reduced P ortCoefficientsValveSize,NPSV
V500 ValveD100054X012Product Bulletin51.3:V500May 201219Table 16. Fisher V500, Forward Flow, Level 4 Trim Full PortCoefficientsValveSize,NPSValve Rota
V500 ValveD100054X012Product Bulletin51.3:V500May 20122SpecificationsAvailable ConfigurationJ Flanged or J flangeless valve assembly(NPS 3 through 8 o
V500 ValveD100054X012Product Bulletin51.3:V500May 201220Table 17. Fisher V500, Reverse Flow, L evel 4 Trim Full PortCoefficientsValveSize,NPSValve Rot
V500 ValveD100054X012Product Bulletin51.3:V500May 201221Table 18. Fisher V500 Forward Flow, Level 4 Trim Reduced PortCoefficientsValveSize,NPSValve Ro
V500 ValveD100054X012Product Bulletin51.3:V500May 201222Table 19. Fisher V500 Reverse Flow, Level 4 Trim Reduced PortCoefficientsValveSize,NPSValve Ro
V500 ValveD100054X012Product Bulletin51.3:V500May 201223
V500 ValveD100054X012Product Bulletin51.3:V500May 201224Emerson Process ManagementMarshalltown, Iowa 50158 USASorocaba, 18087 BrazilChatham, Kent ME4
V500 ValveD100054X012Product Bulletin51.3:V500May 20123Specifications (continued)Shaft DiametersSeefigure5Dimensions and Approximate WeightsSeefigure5
V500 ValveD100054X012Product Bulletin51.3:V500May 20124Table 1. Valve Size, ASME Pressure Ratings, and Flange Compatibility (X indicates availability)
V500 ValveD100054X012Product Bulletin51.3:V500May 2012549A3685-CA3288-2REVERSE FLOW SHUTOFF(STANDARD)FORWARD FLOW SHUTOFFFACE SEALSECTIONFLOWDIRECTION
V500 ValveD100054X012Product Bulletin51.3:V500May 20126Table 3. Maximum Allowable Shutoff Pressure Drops for Level 1 Trim, BarVALVE BODYMATERIALBEARIN
V500 ValveD100054X012Product Bulletin51.3:V500May 20127Table 4. Maximum Allowable Shutoff Pressure Drops for Level 1 Trim, PsiVALVE BODYMATERIALBEARIN
V500 ValveD100054X012Product Bulletin51.3:V500May 20128Table 5. Maximum Allowable Shutoff Pressure Drops for Level 2 and 3 Trims, BarVALVE BODYMATERIA
V500 ValveD100054X012Product Bulletin51.3:V500May 20129Table 6. Maximum Allowable Shutoff Pressure Drops for Level 2 and 3 Trims, PsiVALVE BODYMATERIA