CS800 Series
©Emerson Process Management Regulator Technologies, Inc., 2010, 2014; All Rights Reserved
Industrial Regulators
Emerson Process Management
Regulator Technologies, Inc.
USA - Headquarters
McKinney, Texas 75070 USA
Tel: +1 800 558 5853
Outside U.S. +1 972 548 3574
Asia-Paci c
Shanghai 201206, China
Tel: +86 21 2892 9000
Europe
Bologna 40013, Italy
Tel: +39 051 419 0611
Middle East and Africa
Dubai, United Arab Emirates
Tel: +971 4811 8100
Natural Gas Technologies
Emerson Process Management
Regulator Technologies, Inc.
USA - Headquarters
McKinney, Texas 75070 USA
Tel: +1 800 558 5853
Outside U.S. +1 972 548 3574
Asia-Paci c
Singapore 128461, Singapore
Tel: +65 6770 8337
Europe
Bologna 40013, Italy
Tel: +39 051 419 0611
Chartres 28008, France
Tel: +33 2 37 33 47 00
Middle East and Africa
Dubai, United Arab Emirates
Tel: +971 4811 8100
TESCOM
Emerson Process Management
Tescom Corporation
USA - Headquarters
Elk River, Minnesota 55330-2445, USA
Tels: +1 763 241 3238
+1 800 447 1250
Europe
Selmsdorf 23923, Germany
Tel: +49 38823 31 287
Asia-Paci c
Shanghai 201206, China
Tel: +86 21 2892 9499
The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC,
a business of Emerson Process Management.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or
guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or speci cations of such
products at any time without notice.
Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and
maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser.
For further information visit www.emersonprocess.com/regulators
The distinctive swirl pattern cast into every actuator
casing uniquely identi es the regulator as part of the
Fisher
®
brand Commercial Service Regulator family
and assures you of the highest-quality engineering,
performance and support traditionally associated
with Fisher
®
, Francel™ and Tartarini™ regulators.
Visit www.fishercommercialservice.com to access
interactive applications.
TYPE CS805 SECONDARY SEAT ORIFICE ASSEMBLY (DETAILED VIEW) TYPE CS806 SECONDARY SEAT ORIFICE ASSEMBLY (DETAILED VIEW)
Figure 18. CS800 Series Base Ori ce and Secondary Seat (For Types CS805 and CS806) Assemblies (continued)
APPLY LUBRICANT (L)
(1)
:
L1 = ANTI-SEIZE LUBRICANT
L2 = EXTREME LOW TEMPERATURE BEARING GREASE
1. Lubricants must be selected such that they meet the temperature requirements.
L1
L2
25
82
SECONDARY SEAT™ STANDARD ORIFICE
SEALING
SURFACE
25F
25A
25E
NOTE: RUBBER
INSTALLED
THIS SIDE
PRIMARY
SEATING
SURFACE
SECONDARY
SEATING
SURFACE
EXTREME LOW TEMPERATURE
BEARING GREASE OR COMPARABLE
LUBRICANT THAT MAINTAINS ITS
LUBRICATION PROPERTIES AT
COLD TEMPERATURES
25D
25C
25B
GG00886_F
SEALING
SURFACE
25F
25A
25E
PRIMARY
SEATING
SURFACE
SECONDARY
SEATING
SURFACE
EXTREME LOW TEMPERATURE
BEARING GREASE OR COMPARABLE
LUBRICANT THAT MAINTAINS ITS
LUBRICATION PROPERTIES AT
COLD TEMPERATURES
25D
25C
25B
NOTE: VENT
DISK C’BORE
INSTALLED
THIS SIDE
L1
25
82
L2