Bulletin LP-7:C471/C477
6
C477-16-25 Vertical Up Position
VALVE DIFFERENTIAL PRESSURE, psig / bar
20 /
1.4
18 /
1.2
16 /
1.1
14 /
0.97
12 /
0.83
10 /
0.69
8 /
0.55
6 /
0.41
4 /
0.28
2 /
0.14
0
100 /
379
50 /
189
150 /
568
200 /
757
250 /
946
300 /
1136
FLOW RATE, GPM / L/min PROPANE
Figure 5. Type C477/471-16 Bottom of Tank Position Flow Curve, Half Coupling
0
C477-16-25 Vertical Up Position
L/min Rating
L/min Rating
L/min Rating
Figure 6. Type C477/471-24 Bottom of Tank Position Flow Curve, Half Coupling
C477-24-36
Vertical Up Position
50 /
189
150 /
568
200 /
757
250 /
946
300 /
1136
350 /
1325
400 /
1514
100 /
379
0
0
20 /
1.4
18 /
1.2
16 /
1.1
14 /
0.97
12 /
0.83
10 /
0.69
8 /
0.55
6 /
0.41
4 /
0.28
2 /
0.14
VALVE DIFFERENTIAL PRESSURE, psig / bar
FLOW RATE, GPM / L/min PROPANE
C477-24-36
Vertical Up Position
L/min Rating
L/min Rating
L/min Rating
L/min Rating
450 /
1703