Type ACE95JR
4
This Type ACE95jr tank blanketing valve was
assembled and preset to the customer specied
pressure and setpoint. The control pressure range of
the valve is stamped on the nameplate fastened to the
upper actuator case. The gas blanketing setpoint is the
only adjustable feature on this unit.
1. Get a qualied personnel when installing, operating,
and maintaining valves. Before installing, inspect
the valve and tubing for any shipment damage
or foreign material that may have collected. Make
certain the body interior is clean and the pipelines
are free of foreign material. Apply pipe compound
only to the male pipe threads with a screwed
body, or use suitable line gaskets and good bolting
practices with a anged body.
2. Inspect the nameplate on the upper actuator
case. It displays the model number, serial
number, a blanketing gas supply pressure range,
the maximum inlet pressure, set pressure, and
C
V
value. These must agree with the system that
you are blanketing. The serial number will be
needed in any communication with your local
Sales Ofce.
3. Clean the gas blanketing supply lines of all dirt and
foreign material before connecting them to the
Type ACE95jr tank blanketing valve.
4. The valve must be mounted so the actuator
case is horizontal, as shown in Figure 3. The
valve should be mounted above the tank. Three
connections are required: a) blanketing gas supply
to valve, b) valve outlet to tank, and c) sensing line
to tank.
Figure 3. Type ACE95jr Tank Blanketing Valve Installation
E0620
BLANKETING GAS
SUPPLY LINE
LINE STRAINER
SHUTOFF
VALVE
SENSING
LINE
SHUTOFF
VALVE
SHUTOFF
VALVE
TYPE 252
INLET
FILTER
EMERGENCY
TANK VENT
BLANKETING GAS
TO TANK
TANK VENT
TANK
LIQUID
BLANKETING GAS/VAPOR SPACE
TYPE ACE95jr