Emerson 63EG-98HM Installationsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
2
Type 63EG-98HM
Note
It is important that the relief valve or
backpressure regulator be installed
so that the vent hole in the spring
case is unobstructed at all times. For
outdoor installations, the relief valve or
backpressure regulator should be located
away from vehicular trafc and positioned
so that water, ice and other foreign materials
cannot enter the spring case through
the vent. Avoid placing the relief valve or
backpressure regulator beneath eaves or
downspouts and be sure it is above the
probable snow level.
Overpressure Protection
Maximum inlet pressures depend upon body materials and



Fisher
®
relief
valve or backpressure regulators are NOT ASME safety
relief valves.
Startup


pressure requested, so an initial adjustment may be



Adjustment






Taking Out of Service (Shutdown)
!
WARNING
To avoid personal injury resulting from
sudden release of pressure, isolate the relief
valve or backpressure regulator from all
pressure before attempting disassembly.
BODY SIZE
MAIN VALVE SPRING RANGE,
SPRING PART NUMBER
AND COLOR
MINIMUM DIFFERENTIAL
PRESSURE REQUIRED
FOR FULL STROKE
(1)
BUILDUP OVER SET
PRESSURE REQUIRED
FOR FULL STROKE
MAXIMUM DIFFERENTIAL
PRESSURE
DN 50 / 2 in.


  

14A6626X012, Green
  


  28 bar
(2)

(2)
DN 80 / 3 in.


  

14A6629X012, Green
  


  28 bar
(2)

(2)
DN 100 / 4 in.


  

14A6632X012, Green
  


  28 bar
(2)

(2)
DN 150 / 6 in.
DN 200 x 150 /
8 x 6 in.


  

14A9686X012, Green
  


  28 bar
(2)

(2)



Table 1. Minimum and Maximum Differential and Buildup Required for Wide-Open Flow
MAIN VALVE BODY SIZE MAIN VALVE BODY MATERIAL END CONNECTION STYLES
(1)
STRUCTURAL DESIGN RATING
DN 50 / 2 in.
DN 80 / 3 in.
DN 100 / 4 in.
DN 150 / 6 in.
DN 200 x 150 / 8 x 6 in.

 
 
 
 

Table 2. Body Sizes, End Connection Styles and Main Valve Body Ratings