POWER AVAILABILITY2U Hardwire POD™USER MANUALPower OutputDistribution120 Volt
6INSTALLATION ON GXT 2U UPS1. Unpack the 2U POD carefully, noting the packing method. Retain the box and packing material for possible future shipment
7HARDWIRE CONNECTIONSElectrical Installation Considerations The front and bottom of the POD provide alternate conduit entry points for both the UTILIT
8Wiring access doors on each end of the POD allow access to the wiring compartments by opening the top and rear of the POD. Each access door is retain
9Wiring Instructions1. Remove the wiring access doors by removing the two Phillips head screws that secure them.2. Determine which of the two availabl
10APPLY FEED POWER1. Next attach the POD to the securing brackets (see Figure 7). The POD can be installed to face one of three different directions u
11START EQUIPMENT1. Turn on all loads hardwired to the output of the POD. The 2U POD now powers your equipment in the UTILITY mode.2. Turn ON the load
12INDICATOR LAMPSUtilityThis amber lamp is illuminated when utility power is present. It sig-nals that you may transfer the loads to maintenance bypas
13OPERATIONTransfer to Maintenance BypassTo transfer to maintenance bypass (UTILITY) from UPS, follow the following steps:1. Ensure the Utility lamp (
14TROUBLESHOOTINGProblem Cause SolutionUTILITY lamp (amber) not illuminated.UTILITY not present.Call qualified service personnel to restore power.Util
15SPECIFICATIONSThis POD is intended for use with a UPS meeting all of the following requirements:• UPS input cord is compatible with the rating and t
Technical Support/ServiceWeb Sitewww.liebert.comMonitoring800-222-5877monitoring@liebert.comOutside the US: 614-841-6755Single-Phase UPS800-222-5877up
iTABLE OF CONTENTSIMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . 1GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . . . .
FIGURESFigure 1 UPS mode of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Figure 2 Utility/maintenance bypass mode . . . . . .
1IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important instructions that should be followed during installation and opera
2!CAUTIONThis device receives power from multiple sources. Before servicing this device, remove all connections and cut power from the utility branch
3GLOSSARY OF SYMBOLSEquipment grounding conductorBonded to groundElectric phaseIndicates AC inputIndicates AC output
4INTRODUCTION AND SYSTEM DESCRIPTIONCongratulations on your choice of the Liebert 2U Hardwire POD™. The 2U Hardwire POD provides maintenance bypass ca
5RACK MOUNT INSTALLATION1. Rack mount installation of the 2U POD is possible with the use of the rack mounting brackets (shipped with the POD). See Fi