7
DOWNROD
PIN
HANGER BALL
CEILING COVER
Figure 9A
17. Screw in four 60-watt (maximum) candelabra base
lamps in the housing sockets (Figure 10A). Grasp
the sockets and pivot them until the lamp bulbs are
even with the top of the housing as shown. This will
provide the optimum lighting effect.
18. Securely attach the hanger bracket to the outlet
box using the two screws supplied with the
outlet box (Figure 12A).
The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.
WARNING
!
The fan must be hang with at least 7’ of clearance from
floor to blades (Figure 11A).
WARNING
!
AT LEAST
7'
FLOOR
Figure 11A
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.
WARNING
!
Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.
WARNING
!
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
HANGER
BRACKET
TAB
OUTLET
BOX
Figure 2
Figure 12A
TOP OF
HOUSING
CANDELABRA
BASE LAMP
SOCKET
Figure 10A
19. Carefully lift the fan and seat the hanger
ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 13A).
Be sure the groove in the box is lined up with tab
on the hanger bracket (Figure 12A).
20. Screw two 1-1/4" threaded studs (supplied) into
the tapped holes in the hanger bracket
(Figure 14A).
Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.
WARNING
!
OUTLET
BOX
HANGER
BRACKET
HANGER BALL/
DOWNROD ASSEMBLY
Figure 3
NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.
Figure 13A
To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and the
hanger bracket.
WARNING
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.
WARNING
!