Emerson Fisher 1061 Installationshandbuch Seite 21

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 20
Instruction Manual
D100324X012
1061 F & G Actuator
October 2012
21
Figure 7. Pipe-Away Vent Assembly
DRILL SIZE IS 3.7 TO 4.0 BY 14.2 mm
DEEP (0.145 TO 0.158 BY 0.56-INCH). TAP SIZE I S 9.6 mm
(10-24 UNC-2B BY 0.38-INCH) DEEP,
4HOLES.
DRILL SIZE IS 6.4 TO 6.8 BY 14.7 mm
DEEP (0.252 TO 0.269 BY 0.58-INCH ).
COUNTERSINK HOLE TO 8.4 mm
(0.33-INCH) DIAMETER, 4 HOLES.
DRILLING AND TAPPING PATTERN
ACCESS PLATE ASSEMBLY
SIZE 30, 40, 60, & 68 ACTUATORS
DRILLING AND TAPPING PATTERN
ACCESS PLATE ASSEMBLY
SIZE 80 AND 100 ACTUATORS
ACCESS PLATE ASSEMBLY
MOUNTING YOKE AND COVER ASSEMBLY
HOUSINGVENTPLUGLOCATION
3/4 NPT VENT CONNECTION
1 NPT VENT CONNECTION FOR
SIZE 130 ONLY
NOTE:
FOR FIELD CONVERSION, DRILL AND TAP HOLE PATTERN
IF HOUSING HAS A NON-METALLIC ACCESS PLATE. USE
KEY 137 AS A DRILLING TEMPLATE IF DESIRED OR, USE
THEDIMENSIONSPROVIDEDINTHISFIGUREFORDRILLING
AND TAPPING.
TRAVEL
INDICATOR
6.4
(025)
NOTE:
INSTALL THE HEX HEAD PLUG (KEY 140) INTO THE VENT OPENING
LOCATED IN THE ACTUATOR HOUSING.
V APPLY SEALANT
34B4646-B
34B4647-A
34B4646-B
34B4646-B
40B3945-B
mm
(INCH)
Key Description
135* O-Ring (Nitrile) Hub Side
Size 30/40
12.7 to 22.2 mm (1/2- to 7/8-inch) Shaft
Diameter 1K594906562
Size 40
25.4 to 31.8 mm (1- to 1-1/4-inch) Shaft
Diameter 1K594906562
Size 60
19.1 to 50.8 mm (3/4- to 2-inch) Shaft
Diameter 1U2504X0042
Key Description
136 Travel Indicator Gasket
137 Access Plate Assembly
138 Machine Screw
139 RTV Blue or Equivalent
Silicon Gasket, #6B
140 Plug
Piston/Piston Rod Torquing Fixture
Size 130 58B3070
*Recommended spare parts
Seitenansicht 20