PMC-CGM Installation and Use (6806800D53C)
Controls, LEDs and Connectors LEDs
34
You can find a description of the LEDs in the following table.
Table 3-1 LED Description
Name Description
B1 BITS Interface 1 Status
Green: BITS interface 1 is in use and status is okay
Orange: BITS interface 1 is in use and status is not okay
Red: : BITS interface 1 is out-of-service
OFF: Not defined
B2 BITS Interface 2 Status
Green: BITS interface 2 is in use and status is okay
Orange: BITS interface 2 is in use and status is not okay
Red: : BITS interface 2 is out-of-service
OFF: Not defined
M/S Master/Slave Operation
Green: PMC-CGM operates as Master
Amber: Not defined
Yellow: PMC-CGM operates as Slave
OFF: PMC-CGM is non-operational (by application)
Mode Mode
Green: PMC-CGM operates in locked mode
Amber: PMC-CGM operates in holdover mode
Yellow: PMC-CGM operates in free-run mode
OFF: not defined
OOS Out-Of-Service
Red: PMC-CGM is out-of-service
Off: Not defined
IS In Service
Green: PMC-CGM is in service
Off: Not defined