Emerson 3051S Schnellstart Benutzerhandbuch Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
Quick Installation Guide
00825-0100-4801, Rev KB
December 2010
Rosemount 3051S
6
STEP 1 CONTINUED...
Figure 2. Torque values for the flange and flange adapter bolts
O-rings with Flange Adapters
WARNING
Whenever the flanges or adapters are removed, visually inspect the o-rings. Replace them if
there are any signs of damage, such as nicks or cuts. If you replace the o-rings, re-torque
the flange bolts and alignment screws after installation to compensate for seating of the
PTFE o-ring.
Bolt Material Head Markings Initial Torque Final Torque
Carbon Steel (CS) 300 in.-lbs. 650 in.-lbs.
Stainless Steel (SST) 150 in.-lbs. 300 in.-lbs.
Failure to install proper flange adapter O-rings may cause process leaks, which can result in death or
serious injury. The two flange adapters are distinguished by unique O-ring grooves. Only use the O-ring
that is designed for its specific flange adapter, as shown below.
B7M
316
316
316
SW
316
STM
316
R
B8M
4801_QIG_RevKB.fm Page 6 Friday, December 3, 2010 1:17 AM
Seitenansicht 5
1 2 3 4 5 6 7 8 9 10 11 ... 33 34

Kommentare zu diesen Handbüchern

Keine Kommentare