Emerson 670 Series Panel-Mounted Loading Regulators Datenblatt

Stöbern Sie online oder laden Sie Datenblatt nach Nein Emerson 670 Series Panel-Mounted Loading Regulators herunter. Emerson 670 Series Panel-Mounted Loading Regulators Data Sheet Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Bulletin 62.3:670
D200027X012
February 2015
www.fisherregulators.com
670 Series Panel-Mounted Loading Regulators
P1127_670
1-GAUGE PANEL
(671 AND 670 SERIES)
P1128_670G-3
2-GAUGE PANEL
(670 SERIES)
P1130_670GV
2-GAUGE PANEL WITH
CHANGEOVER VALVE
(670 SERIES)
Figure 1. Typical Panel Layouts
Introduction
The Types 670, 671, 674 and 675 panel-mounted
loading regulators (Figures 1, 2, 3 and 6) are compact,
rugged units used primarily for manually loading
pressure-balanced gas regulators and providing
manual control for diaphragm actuator control valves.
Applications include remote control of gas pressure to
burners in reneries, power plants and various process
furnaces. The Types 670 and 675 units use the
Type 67CR or 67CFR pressure regulator, the Type 671
unit uses the Type 912 pressure regulator and the
Type 674 unit uses the Type 1301F pressure regulator.
Three basic panels are available within the product
line as shown in Figures 1 and 6, each having one
pressure regulator connected to one or two gauges
or two gauges and a changeover valve. A single
gauge typically shows loading pressure to the control
valve. With two gauges, one gauge shows the loading
pressure and the other gauge can be connected to
show downstream control pressure or any other
pressure up to 300 psig / 20.7 bar. Manual backup
of pneumatic controllers can be handled with those
670 Series units having a changeover valve. With it
the operator selects either the automatic controller
output (displayed on one gauge) or the manual
loader output (displayed on the other gauge and
adjusted by the handwheel) as the signal to the
control valve actuator.
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Bulletin 62.3:670

Bulletin 62.3:670D200027X012February 2015www.fisherregulators.com670 Series Panel-Mounted Loading RegulatorsP1127_670 1-GAUGE PANEL (671 AND 67

Seite 2

Bulletin 62.3:6702Available Congurations See Table 1End Connections Inlet: 1/4 NPT internal Outlet: Types 670 and 675—1/4 NPT internal; Type 671—3

Seite 3

Bulletin 62.3:6703W0532Figure 2. Type 670 Panel LoaderW6110-1/ILFigure 3. Side View of Type 671 Panel Loader Using Type 912 Regulator Features • Co

Seite 4

Bulletin 62.3:6704TYPE NUMBERNUMBER OF GAUGEDESCRIPTIONREGULATOR TYPE NUMBERMAXIMUM INLET PRESSUREMAXIMUM OUTLET PRESSUREMAXIMUM EMERGENCY OUTLET PRES

Seite 5

Bulletin 62.3:6705INFigure 6. DimensionsTYPE NO.SERIAL NO.INCREASEMANUALAUTOMATICOFFINTRUMENTLOADING PRESSURELBS PER SQ IN.MANUALLOADING PRESSURELBS P

Seite 6

Bulletin 62.3:6706NOTE: ENVELOPE DIMENSIONS ± 0.25 IN. / ± 6.4 mm1B2405/ILFigure 6. Dimensions (continued)IN. /mm8.00 / 2038.00 / 2031.50 /

Seite 7

Bulletin 62.3:6707InstallationDimensions for installation clearances are shown in Figure 6.Ordering Information When ordering, complete the ordering

Seite 8

Bulletin 62.3:670©Emerson Process Management Regulator Technologies, Inc., 1992, 2015; All Rights ReservedThe Emerson logo is a trademark and service

Kommentare zu diesen Handbüchern

Keine Kommentare