Model 1181 PBDissolved Oxygen Two-Wire TransmitterInstruction ManualPN 51-1181PB/rev.AApril 2003

Seite 2 - ESSENTIAL INSTRUCTIONS

62.6 DISSOLVED OXYGEN SENSOR. The sensorshould be installed in San environment where thetemperature remains between 0 and 44°C (32-110°F).It is used i

Seite 3 - TWO-WIRE TRANSMITTER

7FIGURE 2-1 Mounting and Dimensional DrawingMODEL 1181 PB SECTION 2.0INSTALLATION

Seite 4 - LIST OF TABLES

8MODEL 1181 PB SECTION 2.0INSTALLATIONFIGURE 2-2. Schematic System, F.M. Explosion Proof ApprovedDWG. NO. REV.1400155 C

Seite 5 - SECTION 1.0

9MODEL 1181 PB SECTION 2.0INSTALLATIONFIGURE 2-3. Transmitter WiringPower Wiring (TB1)TB1-1, Loop Signal [Power Supply (+)VDC]*TB1-2, Meter (+) RedTB1

Seite 6 - 1.2 PHYSICAL SPECIFICATIONS –

10MODEL 1181 PB SECTION 2.0INSTALLATIONFIGURE 2-4. Schematic System, F.M. I.S. Approved-Entity (1 of 3)

Seite 7 - 1.5 ORDERING INFORMATION

11MODEL 1181 PB SECTION 2.0INSTALLATIONFIGURE 2-4. Schematic System, F.M. I.S. Approved-Entity (2 of 3)

Seite 8 - SECTION 2.0

12MODEL 1181 PB SECTION 2.0INSTALLATIONFIGURE 2-4. Schematic System, F.M. I.S. Approved-Entity (3 of 3)

Seite 9

13MODEL 1181 PB SECTION 2.0INSTALLATIONFIGURE 2-5. Schematic System, CSA I.S. Approved-LoopDWG. NO. REV.1400157 Bss3 APPROVED FOR CLASS 1, DIVISION 1,

Seite 10 - INSTALLATION

14MODEL 1181 PB SECTION 2.0INSTALLATIONFIGURE 2-6. Flow Chamber with Sensor Dimensions

Seite 11

15MODEL 1181 PB SECTION 2.0INSTALLATIONFIGURE 2-7. Typical Installation with Siphon Breaker

Seite 12 - 1400155 C

DANGERHAZARDOUS AREA INSTALLATIONINTRINSICALLY SAFE INSTALLATIONInstallations in hazardous area locations mustbe carefully evaluated by qualified on s

Seite 13

16MODEL 1181 PB SECTION 3.0DESCRIPTION OF CONTROLSSECTION 3.0DESCRIPTION OF CONTROLS3.1 DESCRIPTION OF CONTROLS.3.1.1 Range Selector Switch. A set of

Seite 14

17MODEL 1181 PB SECTION 3.0DESCRIPTION OF CONTROLSFIGURE 3-2. Display PCB

Seite 15

18MODEL 1181 PB SECTION 3.0DESCRIPTION OF CONTROLSFIGURE 3-3. External Zero and Span Adjust

Seite 16

19MODEL 1181 PB SECTION 3.0DESCRIPTION OF CONTROLSFIGURE 3-4. Digital Display

Seite 17 - 1400157 B

20MODEL 1181 PB SECTION 4.0CONFIGURATIONSECTION 4.0CONFIGURATION4.1 GENERAL The Model 1181PB is factory calibratedto measure 0-200 ppb dissolved oxyge

Seite 18

21MODEL 1181PB SECTION 5.0START UP, AND CALIBRATIONSECTION 5.0START UP AND CALIBRATION5.1 GENERAL. This section provides the start-up andcalibration p

Seite 19 - FIGURE 2-7

22MODEL 1181PB SECTION 5.0START UP, AND CALIBRATION5.3.2 Air Calibration Adjustment for Transmitterswith LCD Digital Display (Code 06).1. Adjust the C

Seite 20 - DESCRIPTION OF CONTROLS

23MODEL 1181 PB SECTION 6.0THEORY OF OPERATIONSECTION 6.0THEORY OF OPERATION6.1 MODEL 1181PB. The Model 1181PB Two-WireTransmitter automatically and c

Seite 21 - FIGURE 3-2. Display PCB

24MODEL 1181 PB SECTION 6.0THEORY OF OPERATION6.2 DISSOLVED OXYGEN MEASUREMENT SENSORRosemount Analytical utilizes the amperometricmembrane technique

Seite 22 - MODEL 1181 PB SECTION 3.0

25MODEL 1181 PB SECTION 6.0THEORY OF OPERATIONSince dry air contains 20.95 oxygen by volume,regardless of the barometric pressure, the partialpressure

Seite 23 - FIGURE 3-4. Digital Display

iModel 1181 PB TABLE OF CONTENTSMODEL 1181 PBTWO-WIRE TRANSMITTERTABLE OF CONTENTSSection Title Page1.0 DESCRIPTION AND SPECIFICATIONS ...

Seite 24 - CONFIGURATION

26MODEL 1181PB SECTION 7.0DISASSEMBLY/ASSEMBLY PROCEDURESECTION 7.0DISASSEMBLY/REASSEMBLY PROCEDURE7.1 DISASSEMBLY PROCEDURE. Disconnect thepower to t

Seite 25 - START UP AND CALIBRATION

27SYMPTOM PROBLEM ACTION1. Abnormally high O2a. Hole in membrane Replace membranereadings (inability tocalibrate) b. Gold cathode loose Replace sensor

Seite 26 - START UP, AND CALIBRATION

28MODEL 1181 PB SECTION 8.0TROUBLESHOOTING/MAINTENANCE8.3 MAINTENANCE. Most routine maintenanceinvolves the sensor. Sensor maintenance consists ofperi

Seite 27 - THEORY OF OPERATION

29MODEL 1181 PB SECTION 8.0TROUBLESHOOTING/MAINTENANCE4. The membrane assembly consists of a Teflonmembrane and three associated parts: a holder,a ret

Seite 28 - MODEL 1181 PB SECTION 6.0

30MODEL 1181 PB SECTION 8.0TROUBLESHOOTING/MAINTENANCE8.3.2 Rejuvenating The Gold Cathode. Typically, thegold cathode is rejuvenated during the rechar

Seite 29

31MODEL 1181 PB SECTION 9.0SPARE PARTSSECTION 9.0SPARE PARTSItem No. Part Number Description Qty.1 3002425 Cover (for Blind Model) 21 3002425 Cover (f

Seite 30 - SECTION 7.0

32MODEL 1181 PB SECTION 9.0SPARE PARTSFIGURE 9-1. Model 1181PB Two-Wire Transmitter Parts

Seite 31 - TROUBLESHOOTING/MAINTENANCE

33MODEL 1181PB SECTION 10.0RETURN OF MATERIALSECTION 10.0RETURN OF MATERIAL10.1 GENERAL. To expedite the repair and return ofinstruments, proper commu

Seite 32 - MODEL 1181 PB SECTION 8.0

FROM: RETURN BILL TO:_____________________________ _____________________________ __________________________________________________________ __________

Seite 33

WARRANTYSeller warrants that the firmware will execute the programming instructions provided by Seller, and that the Goods manufacturedor Services pro

Seite 34

iiModel 1181 PB TABLE OF CONTENTSTABLE OF CONTENTS (CONT'D)LIST OF FIGURESSection Title Page2-1 Mounting and Dimensional Drawing...

Seite 35 - SPARE PARTS

Credit Cards for U.S. Purchases Only.The right people,the right answers,right now.ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITEhttp://www.raihome.com

Seite 36 - MODEL 1181 PB SECTION 9.0

1MODEL 1181 PB SECTION 1.0GENERAL DESCRIPTION AND SPECIFICATIONSSECTION 1.0DESCRIPTION AND SPECIFICATIONS• TWO-WIRE FIELD MOUNTED TRANSMITTERS. Ideal

Seite 37 - RETURN OF MATERIAL

2MODEL 1181 PB SECTION 1.0DESCRIPTION AN SPECIFICATIONS1.2 PHYSICAL SPECIFICATIONS –GENERALEnclosure: NEMA 4X, weatherproof and corrosion-resistant, N

Seite 38 - RETURN OF MATERIALS REQUEST

3MODEL 1181 PB SECTION 1.0DESCRIPTION AN SPECIFICATIONSThe Model 1181PB Transmitter measures dissolvedoxygen in parts per billion. Switch selectable r

Seite 39 - Irvine, CA 92606

4MODEL 1181 PB SECTION 2.0INSTALLATIONSECTION 2.0INSTALLATION2.1 UNPACKING AND INSPECTION. Before openingthe shipping carton, inspect the outside of t

Seite 40 - The right people

5MODEL 1181 PB SECTION 2.0INSTALLATION2.4 WIRING-GENERAL. The transmitter is equippedwith two (2) ¼ -inch conduit openings, one on eachside of the hou