IC200L Series User manual DIXELL
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.10/106 3 IC200 L TABLE OF THE FEATURES IC260L IC261L IC280L IC281L FEATURES C
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.100/106 46 ELECTRICAL CONNECTIONS The instrument is provided with: • 3 removable
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Power supply 230Vac Input 0 - 230Vac output
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.102/106 48 TECHNICAL DATA Housing: self extinguishing ABS. Case: frontal 185x38 mm;
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 4 USER INTERFACE 4.1 FUNCTION OF THE LEDS OF TH
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.12/106 Use of the led on the models IC280L / IC281L Use of the led on the me
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 4.2 USE OF THE LED ON THE MODELS VI620 - VI620S
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.14/106 4.4 KEY FUNCTION KEY ACTION FUNCTION Push and release Show chiller set p
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 4.5 KEY COMBINANTION KEY ACTION FUNCTION Pu
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.16/106 4.7 DISPLAY AND ICONS ICON MEANING / FUNCTIONNING Celsius degrees: ON for
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 4.8 MEANING/ FUNCTIONNING OF THE BOTTOM DISPLAY
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.18/106 7 WIRING CONNECTIONS 7.1 HARDWARE RESOURCES FOR IC260L - IC280L MODELS 10 dig
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 7.3 ANALOG INPUTS NTC – PTC PROBES PbC = Common
INDEX 1 GENERAL ADVICE 7 2 GENERAL FEATURES 8 2.1 MAIN FUNCTION 8 3 IC200 L TABLE OF THE FEATURES 10 4 USER I
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.20/106 7.6 ANALOG INPUT FOR PRESSURE RATIOMETRIC TRANSDUCER PPR30 (0 ÷ 5V SIGNAL) Usi
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 7.8 FAN CONDENSING CONTROL: 0 ÷ 10VDC OUTPUTS Wi
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.22/106 7.10 PROPORTIONAL OUTPUTS 0 ÷ 10V DUMPER CONTROL GND = common 7.11 PROPOR
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 7.12 HOT KEY 64 CONNECTION The programming HOT
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.24/106 7.14 REMOTE PANELS VI620 – VI820 The instrument receives up to two remote pane
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 23. Temperature probe NTC for auxiliary output #
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.26/106 26. Water pump overload of evaporator 1 27. Water support pump overload of e
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Star-delta start: relay linea #2 compressor #1 3
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.28/106 9 TABLE OF THE PARAMETERS MENU SELECTION Label Description ALL Shows all the
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 dP 1 Default read-out of the top display 0 1
12.3 CHILLER – HEAT PUMP FUNCTIONING MODE 46 12.4 KEYBOARD SELECTION 46 12.5 ANALOG INPUT SELECTION 46 13 UNIT START- STOP 47 13.1 START – ST
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.30/106 CF 13 PB6 Configuration If configured as digital input 0 o 1 30 c63 CF 14
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Relay Outputs CF 54 Configuration of RL1 0 -
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.32/106 CF 79 0= from keyboard 1= from digital input 2= from analogue input 0 2
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 ES 17 Energy Saving differential in heat pump
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.34/106 CO 20 Time to make run the pumps together before rotating from one to the o
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Auxiliary relay menu function Parameters Descri
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.36/106 FA 10 Proportional speed control FA01 = 4 Temperature or pressure limit to e
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 FA 28 ON/OFF regulation FA01 = 2/3 SETpoint s
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.38/106 Pr3 Password 0 999 Defrost Parameter Description min max udm Ris
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pr1 Password 0 999 Pr2 Password 0 99
23.3 THERMOREGULATION OF THE SUPPORT HEATERS FOR AIR/AIR UNIT 62 23.4 CONDENSER ANTI-FREEZE HEATERS REGULATION 62 23.
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.40/106 AL 14 Configuration 0= Not enabled 1= Only for chiller 2= Only for heat pum
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 AL 35 Anti-freeze alarm delay in HP for low o
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.42/106 10.2 UPLOAD: HOW TO PROGRAM A “HOT KEY” WITH THE PARAMETERS OF THE INSTRUME
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 3) Inside the family select the “Pr1 - 1”, Pr1
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.44/106 • Leds 1 / 2 are blinking: the parameter can not be changed. • All the l
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 11.9 MOVE A PARAMETER FROM PR3 TO PR2 TO PR1 Ent
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.46/106 12 SELECTION AND START OF THE RUNNING MODE 12.1 SELECT THE CHILLER OR THE HEA
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 13 UNIT START- STOP The unit start sotp can be d
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.48/106 Fig.2 15 CUSTOM DISPLAY The dP family of parameters allows to set a custom
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 dP01=13 NTC temperature probe of the combined d
38 DEFROST CYCLE 77 38.1 FORCED DEFROST 77 38.2 COMBINED DEFROST 77 38.3 MANUAL DEFROST 78 38.4 DEFROST START CONDITION WITH TWO CIRCUIT UNIT
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.50/106 15.2 DEFAULT READ - OUT OF THE BOTTOM DISPLAY To set the default value displa
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Bottom display: circuit 2: • Evaporator 2 water
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.52/106 16.4 DISPLAY IN REMOTE OFF From digital input configured as remote ON/OFF: t
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 7. Repeat operation 1 – 5 to reset the other al
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.54/106 4. Push SET for 3 seconds when the label corresponds to the compressor to dis
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 17.16 READ-OUT OF THE PROPORTIONAL OUTPUT PERCEN
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.56/106 FUNCTION trEM to show the temperature of the remote panels Identification labe
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Energy saving or unit ON/OFF with RTC and X Y w
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.58/106 The regulation is enabled if: • In chiller mode the parameter Sd01 is not equ
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 20 AUXILIARY RELAYS The auxiliary relays can be
45.2 PLEXIGLASS PROTECTION BOTTOM OPEN 98 45.3 PLEXIGLASS PROTECTION TOP OPEN 98 45.4 METAL FRONT FRAME 99 45.5 VE
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.60/106 Par. ST04 Heat pump setpoint It allows to set the Heat pump working temperatur
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 22.2 GRAPH OF THE COMPRESSOR THERMOREGULATION
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.62/106 The thermoregulation, the anti-freeze alarm and the relay outputs for heaters
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 23.6 GRAPH OF THE ANTI-FREEZE- INTEGRATION HEATI
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.64/106 25 THERMOREGULATION AND COMPRESSORS ROTATION The CO14 parameter determines the
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Fig. 1 27.3 DIRECT START- UP OF A CAPACITY CO
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.66/106 Set Par CF56 = 23. Star-delta centre relay of the compressor #1; 27.8 STAR -
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Compr. Compressor ON Compressor ON Compressor O
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.68/106 Having one compressor with 3 partializations, with CO07=2 when the compressor
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 If the thermoregulation is stopped via digital i
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 1 GENERAL ADVICE • 1.1 PLEASE READ BEFORE USING
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.70/106 ATTENTION If the pump down function is enabled, during the unit start-up from
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 30.4 UNLOADING WITH PRESSURE, CONDENSING TEMPE
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.72/106 ATTENTION The display resolution is 0.1°C until the read-out is 99.9, over 10
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Note: During the defrost and when the compresso
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.74/106 36 LOAD MAINTENANCE PARAMETERS CO26..CO31 are the set of the running hour coun
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 37.1 OUTPUT STEP RELE’ CONDENSER FAN Par FA01
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.76/106
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 37.5 GRAPH: ON / OFF REGULATION OF THE CONDENSER
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.78/106 The count-down to the defrost cycle starts when the temperature/pressure of th
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 If df07 <> 0: 1. The compressors and the
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.8/106 2 GENERAL FEATURES iCHILL IC200L is an electronic controller for chiller un
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.80/106 dF06 defrost delay time between the 1st and the 2nd circuit. After the interv
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 39 RECOVERY The recovery function is Enabled if:
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.82/106 When the system is running with 100% (eg all the three compressor of a circuit
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 40.2 RECOVERY ENABLED If the temperaTure/pressur
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.84/106 CO16 / CO21=2 Compressor on – pump on The alarm is managed only if one digital
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 41.8 AFR: POWER SUPPLY FREQUENCY ALARM Label on
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.86/106 ACF6 • The total number of compressor of the 2 circuits ( CF04 + CF05 ) is:
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Unit ON/OFF Disabled if based on RTC 41.
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.88/106 41.16 ACP1 - ACP12 CONDENSER PUMPS MAINTENANCE REQUEST Label description ACP1
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 41.20 B1AH - B2AH ANTI-FREEZE ALARM / LOW OU
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 • Low evaporating pressure Maintenance messages
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.90/106 Origin The alarm is activated when at least one of the probes , configured as
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Origin The compressor discharge temperature is h
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.92/106 41.32 B1RC – B2RC RECOVERY DISABLED FROM HIGH CONDENSING TEMPERATURE/PRESSU
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Origin Pump/supply fan running hours > Hour
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.94/106 41.37 ACP1 - ACP1 CONDENSER PUMP MINTENANCE Label o the display ACP1 (Condens
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 43 TABLE OF THE OUTPUT STATUS IN ALARM CONDITIO
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.96/106 ArtF Faulty clock ArtC Clock error AEUn Unloading signalli
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 43.3 ALARM: “A” TYPE AND CORRESPONDING COMPRESS
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 Pg.98/106 44 BLACK-OUT After the black-out is restored: 1. The instrument resores the
1592015300 User manual iCHILL 200 L GB r1.3 09/09/2005 45.4 METAL FRONT FRAME 45.5 VERTICAL