Emerson CSI 9420 Bedienungsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
1
2
3
4
Input
Accelerometer 1
- DC Bias Range: 2 - 3 Vdc
- DC Input Range: 0 - 5 Vdc
- AC Input Range: + 2.5 Vpeak
(100 gs peak)
Accelerometer 2
- DC Bias Range: 2 - 3 Vdc
- DC Input Range: 0 - 5 Vdc
- AC Input Range: + 2.5 Vpeak
(100 g’s peak)
Temperature 1
- DC Bias Range: N/A
- DC Input Range
-22° F to 302° F (-30° to + 12 C)
- AC Input Range: N/A
Ouput
HART enabled, wireless, linear with
velocity, temperature, and/or PeakVue
The overall velocity measurement
delivered over the 2Hz-1000Hz
frequency range per the ISO 10816
standard.
The PeakVue value delivered as peak-
to-peak acceleration value based on a
1000Hz high-pass filter
Local Display
The optional five-digit integral LCD
Meter can display engineering units
(°F, °C, In/Sec, mm/sec and g’s).
Display updates at transmit rate up to
once per minute
Humidity Limits
0–100% relative humidity
Temperature Limits
Without LCD Meter Display
Operating Limit Storage Limit
-32° F to 185° F -32° F to 185° F
-40° C to 85° C -40° C to 85° C
With LCD Meter Display
Operating Limit Storage Limit
-4° F to 185° F -32° F to 185° F
-20° C to 85° C -40° C to 85° C
Transmit Rate
User selectable, 1 min to 60 min
A0394 Sensor Series
Nominal Sensitivity
25 mV/g (2.5mV/(m/s
2
)
Frequency Range
96 to 600k cpm (1.6 to 10k Hz)
Amplitude Range
± 80 g 784 m/s
2
)
Broadband Resolution
3 mg rms (29 mm/s
2
rms)
Settling Time
2 sec (≤ 2 sec)
Temperature Range
-65 to +250° F (-54 to +121° C)
Connector Position
Side (Side)
Weight
0.81 oz (23 gm)
Functional Specifications
ElectroMagnetic Compatibility (EMC)
All Models meets all relevant
requirements of EN 61326.
Measurement Accuracy
Parameter - Typical
2
- RMS Velocity +/- 0.4 dB
(Corresponds to +/-4%)
- PeakVue +/- 0.4 dB
(Corresponds to +/- 4%)
- Temperature +/- C
NOTE: (1) Measurement accuracy is the absolute accuracy of
the measurement relative to a known, calibrated excitation for
WirelessHART devices.
(2) Typical measurement accuracy represents the expected
performance operating under steady-state conditions (constant
temperature at 20°C with no external interference) for a mid-band
excitation (nominally 1 g at 100 Hz). This variation includes the
frequency response of the electronics and the sensor
Measurement Precision
Vibration: +/- 0.2 dB over 24 months
Temperature: +/- 2 °C over 24 months.
Self Calibration
The analog-to-digital measurement
circuitry automatically self-calibrates for
each update by comparing the dynamic
measurement to extremely stable and
accurate internal reference elements
Vibration Effect
No loss in functionality when tested per
the requirements of IEC60770-1 with
high vibration level (10 Hz to 10 Khz)
and up to 50g acceleration
Sensor Connections
Connecting One Sensor to the CSI 9420
Connecting One Sensor / accelerometer
- Connector labeled 1 - Red wire
- Connector labeled 2 - White wire
- Connector labeled 3 - Blank
- Connector labeled 4 - Black wire
Connecting Two Sensors to the
CSI 9420
Connecting Two Sensors /
accelerometer
- Connector labeled 1 - Two red wires
(one from each sensor)
- Connector labeled 2 - White wire from
one sensor
- Connector labeled 3 - White wire from
other sensor
- Connector labeled 4 - Two black wires
(one from each sensor)
Connecting One Sensor with
Temperature to the CSI 9420
Connecting One Sensor accelerometer
with temperature
- Connector labeled 1 - Red wire
- Connector labeled 2 - White wire
- Connector labeled 3 - Green wire
- Connector labeled 4 - Black wire
Performance Specifications
Wireless Power Module
Replaceable, intrinsically safe
Lithium-Thionyl Chloride power module
pack with PBT enclosure
Power Module life Transmit Rate
- Active LCD Panel
3.5 years : 30 minute transmit rate
6 years: 60 minute transmit rate
- No LCD Panel
4 years: 30 minute transmit rate
7 years: 60 minute transmit rate
Sensor Terminals
Screw terminals permanently fixed to
terminal block
HART Communicator Connections
Communication Terminals
Clips permanently fixed to terminal
block
Materials of Construction
Enclosure
Housing - Low-copper aluminum
Paint - Polyurethane
Cover O-ring - Buna-N
Terminal Block and Battery Pack
PBT
Antenna
PBT/PC integrated omni directional
antenna
Mounting
Transmitters may be attached away
from the asset to be monitored with the
sensors mounted directly to the asset
Mounting brackets also permit remote
mounting. See the “Dimensional
Drawings” section
Weight
CSI 9420 without LCD - 4.6 lbs. (2 kg)
CSI 9420 with M5 LCD - 4.7 lbs (2.1 kg)
Enclosure Ratings (9420)
Housing option code D is NEMA 4X,
and IP66
(1) Reference conditions are for one accelerometer connected at 70°
F (21° C), and routing data for three additional network devices.
NOTE: Continuous exposure to ambient temperature limits (-40 °F
or 185 °F) (-40 °C or 85 °C) may reduce specified battery life by less
than 20 percent.
Physical Specifications
Product Data Sheet
January 2009
Page 5
Seitenansicht 4
1 2 3 4 5 6 7 8 9 10

Kommentare zu diesen Handbüchern

Keine Kommentare