Emerson 3051S Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Nein Emerson 3051S herunter. Emerson 3051S User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
www.rosemount.com
¢00825-0100-4801J¤
HART
®
Quick Installation Guide
00825-0100-4801, Rev HA
February 2008
Rosemount 3051S
Rosemount 3051S Series Pressure
Transmitter with HART
®
Protocol
Rosemount 3051SF Series Flowmeter
Transmitter with HART
®
Protocol
© 2008 Rosemount Inc. All rights reserved. All marks property of owner. Rosemount and the
Rosemount logotype are registered trademarks of Rosemount Inc.
Step 1: Mount the Transmitter
Step 2: Consider Housing Rotation
Step 3: Set Switches and Jumpers
Step 4: Connect Wiring and Power Up
Step 5: Verify Configuration
Step 6: Trim the Transmitter
Safety Instrumented Systems
Product Certifications
Start
End
4801_QIG_RevHA.fm Page 1 Tuesday, February 26, 2008 12:17 PM
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - ¢00825-0100-4801J¤

www.rosemount.com¢00825-0100-4801J¤HART® Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051SRosemount 3051S Series Pressure Tr

Seite 2 - IMPORTANT NOTICE

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 10STEP 4 CONTINUED...NOTEWire colors provided on page 9 are per Belden 308

Seite 3

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S11STEP 4 CONTINUED...2. Place coupling nut over quick connect and wrench ti

Seite 4 - STEP 1: MOUNT THE TRANSMITTER

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 12STEP 4 CONTINUED...Power SupplyThe dc power supply should provide power

Seite 5

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S13STEP 5: VERIFY CONFIGURATIONUse any HART-compliant master to communicate

Seite 6

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 14STEP 5 CONTINUED...Function Fast Key SequenceSaturation Level Configurat

Seite 7

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S15STEP 6: TRIM THE TRANSMITTERTransmitters are shipped fully calibrated per

Seite 8

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 16Using the Transmitter Zero Adjustment ButtonPush and hold the zero adjus

Seite 9

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S17SAFETY INSTRUMENTED SYSTEMSAdditional Safety Instrumented Systems informa

Seite 10 - Rosemount 3051S

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 18InstallationNo special installation is required in addition to the stand

Seite 11 - 32-in hex wrench

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S19NOTES1. Transmitter output is not safety-rated during the following: conf

Seite 12

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 2Rosemount Inc.8200 Market BoulevardChanhassen, MN USA 55317T (US) (800) 9

Seite 13 - STEP 5: VERIFY CONFIGURATION

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 20Setting the alarm values and direction is dependent on whether or not th

Seite 14

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S21Operation and MaintenanceProof Test and InspectionThe following proof tes

Seite 15 - STEP 6: TRIM THE TRANSMITTER

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 22Proof Test 2This proof test, when combined with the Proof Test 1, will d

Seite 16

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S23ReferenceCertificationThe 3051S Safety-Certified Pressure Transmitter was

Seite 17 - SAFETY INSTRUMENTED SYSTEMS

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 24PRODUCT CERTIFICATIONSApproved Manufacturing LocationsRosemount Inc. — C

Seite 18

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S25Hazardous Locations CertificationsNorth American CertificationsFM Approva

Seite 19

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 26European CertificationsI1 ATEX Intrinsic SafetyCertificate No.: BAS01AT

Seite 20

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S27Special Conditions for Safe Use (x)The apparatus is not capable of withst

Seite 21

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 28E1 ATEX Flame-Proof Certificate No.: KEMA00ATEX2143X II 1/2 GEEx d IIC

Seite 22

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S29Australian Certifications E7 SAA Explosion-Proof and Dust Ignition-ProofC

Seite 23

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S3WARNINGExplosions could result in death or serious injury: Installation of

Seite 24 - PRODUCT CERTIFICATIONS

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 30I7 IECEx Intrinsic SafetyCertificate No.: IECExBAS04.0017XEx ia IIC T4 (

Seite 25

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S31Combinations of CertificationsStainless steel certification tag is provid

Seite 26

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 324801_QIG_RevHA.fm Page 32 Wednesday, February 20, 2008 9:16 AM

Seite 27

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S334801_QIG_RevHA.fm Page 33 Wednesday, February 20, 2008 9:16 AM

Seite 28

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 344801_QIG_RevHA.fm Page 34 Wednesday, February 20, 2008 9:16 AM

Seite 29

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S354801_QIG_RevHA.fm Page 35 Wednesday, February 20, 2008 9:16 AM

Seite 30 - OUNDATION fieldbus

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 36NOTES4801_QIG_RevHA.fm Page 36 Tuesday, February 26, 2008 12:17 PM

Seite 31

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 4STEP 1: MOUNT THE TRANSMITTERLiquid Flow Applications1. Place taps to the

Seite 32

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S5STEP 1 CONTINUED...Panel Mount Pipe MountCoplanar™ Flange Traditional Flan

Seite 33

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 6STEP 2: CONSIDER HOUSING ROTATIONSTEP 3: SET SWITCHES AND JUMPERSIf alarm

Seite 34

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S7STEP 4: CONNECT WIRING AND POWER UPUse the following steps to wire the tra

Seite 35

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S 8STEP 4 CONTINUED...Remote Display Wiring and Power UpThe Remote Mount Dis

Seite 36

Quick Installation Guide00825-0100-4801, Rev HAFebruary 2008Rosemount 3051S9STEP 4 CONTINUED...Intrinsic Safety Consideration: The transmitter assembl

Kommentare zu diesen Handbüchern