Precision Cooling for
Business-Critical Continuity
Liebert HPM
Designed for top level performance and reliability
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Liebert HPM

Precision Cooling forBusiness-Critical ContinuityLiebert HPMDesigned for top level performance and reliability

Seite 2 - Financial networks

Connectivity and monitoring solutionsWhether you have a Network Management Systemor a BMS and you need to integrate Liebert HPM,this can be simply don

Seite 3 - The product

Embedded Ethernet connectionEach unit connected to Ethernet can talk to up to 32 units regardless of the distance.EthernetIPIPIPIPIPIPIPdisplayWheneve

Seite 4 - Reliability

Functional schemesA - Air-cooledwith remote condenserD - Air-cooled Dual-FluidW- Water-cooledH - Water-cooled Dual-Fluid C - Chilled waterF - Freecool

Seite 5

Combination with condensersMax. outdoor temperature 35° CModel Standard Low Noise S04 A 1 x HCE07 1 x HCE 07S05 A 1 x HCE07 1 x HCE 07S07 A 1 x H

Seite 6 - Flexibility

Technical data - C - Chilled waterAir delivery: downwards or upwardsModel S06 S08 S11 S15 S18 S29 M44 M55 M66 M77 L90(6)L10(6)L12(6)L14(6)L15(6)Total

Seite 7 - Copeland Digital Scroll™

Technical data - C - Chilled waterAir delivery: downwards or upwardsModel L16(6) (8)L18(6) (8)L20(6) (8)Total cooling capacity(2)kW 175,0 206,8 232,2

Seite 8 - Running cost

Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.Emerson N

Seite 9 - Heat exchange

Data CenterFinancial networksEmerson Network Power, a Division of Emerson, is a global com-pany matching technology and design to supply innovative so

Seite 10

The productLiebert HPM units are cabinet air condi-tioners. They can feature EC fans,with several air delivery versions: downwards, that is with under

Seite 11 - Ethernet

DesignLiebert HPM has been especially designed toachieve top reliability. All components havebeen sized for the lowest possible stress. Mod

Seite 12 - A - Air-cooled

Ethernetcontrol• Several graphic display options• On-line unit log• Integrated Web communication• Preventive maintenance through anadvanced troublesho

Seite 13 - Combination with Dry Cooler

EC fansVariable speed fans achieve a wide range of airdelivery and static pressure. They ensure a cor-rect air distribution even when the facili

Seite 14

EthernetEC fans • AC powered 50/60 Hz without frequen-cy converter• Static pressure continuous adjustment• Energy consumption lower by approx.30% vs.

Seite 15

EfficiencyCooling a computer room needs high power. Energy efficiency is the top target in LiebertHPM designing. Over-sized heat exchangers and

Seite 16

EthernetHeat exchange surface• High Energy Efficiency Ratio (EER). Itbasically depends on the heat exchangesurface.Refrigerating circuits consume less